SMC Corporation of America
Elite Part Number Search
Search Results "AS1200-M3-J"

Otherwise, chattering will occur. -56No.PS-OMM0005-J Piping specifications Model No.

Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm. -14No.PS-OMM0003-J Mounting with panel mount adapter -15No.PS-OMM0003-J Piping Connection using screw type piping Connect suitable piping to the port.

DRod Boot Material Symbol Rod boot material -X J Nylon tarpaulin K Heat resistant tarpaulin Individual -X Maximum ambient temperature for the rod boot itself.

0 Body Valve side exhaust Refer to the back of page 465 for Maintenance Parts. 457 A XLS Series Dimensions XLS/Without control power supply D Lead wire AWG20, O.D.: 2.63 mm E D F L J K 2 J K L 270 10 290 10 M J K J 33 25 C B 39 G G1/2 G1/2 C B B C A B C 6 to 9 G1/2 A DIN terminal (D) Terminal (T) Conduit (C) Grommet (G) XLS/With control power supply 41 26 J K 530 10 72 OPERATION V INPUT

Use two M3 screws for mounting the sensor head(prepare separately). Recommended tightening torque for M3 screw : 0.61 to 0.63Nm. 7 Mate M3 bolt to the bolt mount surface. Mounting from the opposite side leads to cause the breakage of the sensor head. The sensor head body is common with GND due to the sensor structure.

x 0.5 (port size) 2-M3 x 0.5 (port size for axial piping type MTS8-P) 9 2-M3 x 0.5 Effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 M2.5 x 0.45 12 41 + Stroke 53 + Stroke 9 15 0.2 9 4-M3 x 0.5, effective length 5 10 15 0.2 Rod end male threads Width across flats 3.5 +0.035 +0.025 4 M3 x 0.5 3.9 M3 x 0.5 6.4 7 8 4 24 5.5 2.4 Stud bolt part number: MT-S8 Rod end nut part number: NTJ-006A

PFM5-(N)01/(N)02/F01-1/2 -25No.PF-OMJ0016-J PFM5-(N)01L/(N)02L/F01L-1/2 -26No.PF-OMJ0016-J PFM5S-(N)01/(N)02/F01-1/2 -27No.PF-OMJ0016-J PFM5S-(N)01L/(N)02L/F01L-1/2 -28No.PF-OMJ0016-J PFM5-F02-1/2 -29No.PF-OMJ0016-J PFM5-F02L-1/2 -30No.PF-OMJ0016-J PFM5S-F02-1/2 -31No.PF-OMJ0016-J PFM5S-F02L-1/2 -32No.PF-OMJ0016-J PFM5-C/N-1/2 -33No.PF-OMJ0016-J PFM5-C/NL-1/2 -34No.PF-OMJ0016-J PFM5S-C/N

H1 D 0 E0.05 I C R0.4 Width across flats B1 8 x J Width across flats NA Width across flats KA TZ ZZ + Stroke Z + Stroke With air cushion 2 x P (Rc, NPT, G) GA WA GB WB W 10 Cushion valve, Width across flats WH With rod boot 8 8 h + l IJ e JH JW f l ZZ + l + Stroke Z + l + Stroke (mm) Bore size Stroke range Rc, NPT port G port A AL B1 C CD CZ D E F H H1 I J K KA L MM NA Standard Long stroke

0 Body Valve side exhaust Refer to the back of page 465 for Maintenance Parts. 457 XLS Series Dimensions XLS/Without control power supply D E D F L J K 2 J K L 270 10 290 10 M J K J 33 25 C B 39 G G1/2 G1/2 C B B C A B C 6 to 9 G1/2 A DIN terminal (D) Terminal (T) Conduit (C) Grommet (G) XLS/With control power supply 41 26 J K 530 10 72 OPERATION V INPUT C B L (mm) Grommet (G) A B C

L B + Stroke A + Stroke CE1 CE2 Rod end male thread ML2B H1 C J G5-S Auto switch D-A9, F9 CV MVGQ Rod end nut C1 X L1 CC RB Rod End Male Thread (mm) Bore size (mm) C1 X H1 L1 J 32 20.5 23.5 28.5 M14 x 1.5 D40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40

x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 RZQ MI W S CEP1 CE1 CE2 ML2B C J G5-S CV MVGQ CC RB J D-X 20Data 10-4-17

Bowl assembly / auto drain for AWM30-D Option symbol Semi-standard symbol 6 J 6J Semi-standard: J Semi-standard: (Standard) (9) Part No. Piping port thread ty pe Piping port thread ty pe (9) Part No. Rc C3SF-J-D G C3SFF-J-D NPT C3SFN-J(Z)-D Rc G NPT C3SF(-Z)-D C3SF-D Appearance and part No.

(When automatic fluid filling [Option J] is selected.) Overflow port This is necessary when automatic fluid filling function.Discharge excess circulating fluid when the fluid level in the tank rises. (When automatic fluid filling [Option J] is selected.)

(With 2 input blocks) With External Pilot Specifications 46.5 (Pitch) 2-M12 M3 16.5 18.3 13.5 P = 10.5 14.1 8.4 SV 8.6 10 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 17.7 24.6 23 59.5 SZ 3 3 PWR 3 3 42.7 5 3 E 3 5 E 5 3 E 3 5 E T T 43 PWR 56.5 2 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" 1 1 1 1 BUS 4632

x 0.5 depth 5 2 x 1.2 (Guide air release) 9 + Stroke 5 [ 6.7] 20.5 20.5 20.5 3 5 28 29 9 2 [Auto switch] 2 x M3 x 0.5 (port size) 6.1 + Stroke 8.4 6 9 12 14.5 MGJ 10 4 x M4 x 0.7 depth 5 2 x M3 x 0.5 through 2 x 4.3 through Counterbore 8 depth 0.5 25 + Stroke MGP 5 19 + Stroke 8 [ 24.5] 10.5 + Stroke 2 x 2 through (Guide air release) MGQ MGG 6 MGC [ 6.7] 5 32 23 11 23 33 23 3 MGF MGZ 6 [

Fixing hexagon socket head bolt M3 L-bracket DIN rail mounting bracket Spacer Hexagon nut M3 14 - 4-3.Wiring table Cable color Necessity of wiring Signal name I/O Specification No. Power supply +24 V 1 Brown 2 Blue Power supply GND 3 Orange Discharge stop signal Input When the signal is turned off, discharge stops.

(When automatic fluid filling [Option J] is selected.) Overflow port This is necessary when automatic fluid filling function.Discharge excess circulating fluid when the fluid level in the tank rises. (When automatic fluid filling [Option J] is selected.)

(When automatic fluid filling [Option J] is selected.) Overflow port This is necessary when automatic fluid filling function.Discharge excess circulating fluid when the fluid level in the tank rises. (When automatic fluid filling [Option J] is selected.)

The weight will increase by 1kg when option J [Automatic fluid filling] is selected.

Table 6.1-1 Specification of earth leakage breaker Model Rated current [A] Sensitivity of leak current [mA] HRS050-A-20-B-R 20 30 6.2 Option J [Automatic fluid filling] 6.2.1 Option J [Automatic fluid filling] This function is available for customers who selected automatic fluid filling.