To secure the emitter cartridge with a screw, use an M3 x 0.5 12mm cross recessed round head screw (The screw needs to be prepared by the user). M3 screw recommended tightening torque is 0.25 to 0.35 Nm. Install the ionizer so that the emitter cartridge can be removed for maintenance and replacement of the emitters.
Basic style Width across flats 3.5 23 9 4.5 4.5 MXH MXU 6.5 3.5 2 x M3 x 0.5 (Port size) MXS 2 x M3 x 0.5 MXQ (Port size for axial piping type MTS8-P) 0.2 2 x M3 x 0.5, effective length 5 9 5 MXF +0.035 +0.025 4 MXW 22 12 16 MXJ M2.5 x 0.45 12 41 + Stroke MXP 53 + Stroke 9 15 MXY MTS 0.2 9 4 x M3 x 0.5, effective length 5 10 15 Rod end male thread Width across flats 3.5 +0.035 +0.025 4 M3
Range Setting Enabled Section Setup M3*9 2 SVCMD_IO (input signal monitor) Allocation 4 0 to 1717 0 Immediately Pn863 Setup M3*9 2 SVCMD_IO (input signal monitor) Allocation 5 0 to 1717 0 Immediately Pn864 Setup M3*9 2 SVCMD_IO (input signal monitor) Allocation 6 0 to 1717 0 Immediately Pn865 Setup M3*9 2 SVCMD_IO (input signal monitor) Allocation 7 0 to 1717 0 Immediately Pn866 9
(mm) IZN1007 (inch) 3.5 2 x M3 x 0.5 depth 10 26 32 7 25.8 Note 1) 11 Note 1) Dimensions of the resin part stated in Provide Grounding on page 454.
8 5 Width across flats 12 10.6 17 Nozzle Type Ionizer IZN10E Series Dimensions L-bracket IZN10-B1 17 (Mounting angle adjustable range) 40 2 x M3 7.5 2 x 3.4 2 x R10 25 5 40 50 Internal mounting 2 x 3.4 20.5 33 30 30 52 46 44 26 17 11 26 12 8 x 3.4 2 x Hexagon socket head cap screw M3 x 6 (Accessory) 40 5 22.7 Internal mounting Pivot mounting 21 33 30 (Mounting angle adjustable range) (83)
/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 167 Series KK Flow Characteristics Air (0 to 1 MPa) Water (0 to 0.4 MPa) KK2 KK2 0.007 0.50 Series KK2 (KK2S-M5M + KK2P-M5M) Series KK2 (KK2S-M5M + KK2P-M5M) 0.45 0.006 0.40 0.005 0.35 Flow rate m3/min (ANR) Flow rate m3/min Flow rate m3/min 0.30 0.004 0.25 0.003 0.20
Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Mounting screw M3 x 5L The tightening torque for bracket mounting screw should be 0.5 to 0.7 Nm.
Series AS Speed Controller with One-touch Fitting Elbow Type/Universal Type How to Order 2 2 0 01 06 S AS 1F Hexagon lock nut Round lock nut J Nil Lock nut option Body size AS AS 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order (Refer to page 490 for details.)
Width across flats 3.5 23 9 4.5 4.5 6.5 3.5 2-M3 x 0.5 (Port size) 2-M3 x 0.5 (Port size for axial piping type MTS8-P) 9 2-M3 x 0.5, effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 41 + Stroke M2.5 x 0.45 12 53
0.4 J 0.65 J 1.2 J Rubber bumper CM3 Female thread 0.11 J 0.18 J 0.29 J 0.52 J Allowable kinetic energy Male thread 0.54 J (11.0) 0.78 J (11.0) 1.27 J (11.0) 2.35 J (11.8) Air cushion CG1 (Effective cushion length (mm)) Female thread 0.11 J 0.18 J 0.29 J 0.52 J Refer to pages 262 to 266 for cylinders with auto switches CG3 * Operate the cylinder with in the allowable kinetic energy.
(Example) CDA2WL40-100 Nil J K Nil JJ KK Nil N Cylinder stroke (mm) For more information, please refer to the next page.
Center Trunnion Style: CA2T With rod boot Z + 1/2Stroke Width across flats KA 4 x J G G 2 x P (Rc, NPT, G) 2 x cushion valve MM TDe8 D E e TY B C d B1 f 10.2 l H1 B C AL h + l K A N F TT N ZZ + l + Stroke TX TZ S + Stroke H ZZ + Stroke (mm) Stroke range (mm) A Bore size (mm) AL B B1 C D E F G H1 J K KA MM N P Without rod boot With rod boot 40 Up to 500 20 to 500 30 27 60 22 44 16 32 10 15
-J Dimensions PFM7-(N)01/(N)02/F01 -59No.PF-OMJ0006-J PFM7-(N)01L/(N)02L/F01L -60No.PF-OMJ0006-J PFM7S-(N)01/(N)02/F01 -61No.PF-OMJ0006-J PFM7S-(N)01L/(N)02L/F01L -62No.PF-OMJ0006-J PFM7-F02 -63No.PF-OMJ0006-J PFM7-F02L -64No.PF-OMJ0006-J PFM7S-F02 -65No.PF-OMJ0006-J PFM7S-F02L -66No.PF-OMJ0006-J PFM7-C4/C6/C8/N7 -67No.PF-OMJ0006-J PFM7-C4L/C6L/C8L/N7L -68No.PF-OMJ0006-J PFM7S-C4/C6/C8/N7
Otherwise, chattering will occur. -56No.PS-OMM0005-J Piping specifications Model No.
Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm.
DRod Boot Material Symbol Rod boot material -X J Nylon tarpaulin K Heat resistant tarpaulin Individual -X Maximum ambient temperature for the rod boot itself.
0 Body Valve side exhaust Refer to the back of page 465 for Maintenance Parts. 457 A XLS Series Dimensions XLS/Without control power supply D Lead wire AWG20, O.D.: 2.63 mm E D F L J K 2 J K L 270 10 290 10 M J K J 33 25 C B 39 G G1/2 G1/2 C B B C A B C 6 to 9 G1/2 A DIN terminal (D) Terminal (T) Conduit (C) Grommet (G) XLS/With control power supply 41 26 J K 530 10 72 OPERATION V INPUT
Use two M3 screws for mounting the sensor head(prepare separately). Recommended tightening torque for M3 screw : 0.61 to 0.63Nm. 7 Mate M3 bolt to the bolt mount surface. Mounting from the opposite side leads to cause the breakage of the sensor head. The sensor head body is common with GND due to the sensor structure.
x 0.5 (port size) 2-M3 x 0.5 (port size for axial piping type MTS8-P) 9 2-M3 x 0.5 Effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 M2.5 x 0.45 12 41 + Stroke 53 + Stroke 9 15 0.2 9 4-M3 x 0.5, effective length 5 10 15 0.2 Rod end male threads Width across flats 3.5 +0.035 +0.025 4 M3 x 0.5 3.9 M3 x 0.5 6.4 7 8 4 24 5.5 2.4 Stud bolt part number: MT-S8 Rod end nut part number: NTJ-006A