SMC Corporation of America
Elite Part Number Search
Search Results "AL40-06-2-A"

Metric size Inch size Body size Port size 3 1/8 standard 06 6 07 1/4 Symbol Cylinder side 4 1/4 standard 08 8 09 5/16 01 R1/8 5 3/8 standard 10 10 11 3/8 02 R1/4 6 1/2 standard 12 12 13 1/2 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series Applicable tubing O.D.

-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.

Order a stainless steel screw kit (BBA1) separately, and use the M4 x 6 L stainless steel set screws included in the BBA1. Note 5) There is a difference in the cylinder tube thickness depending on the cylinder model. Use caution when a band mounting type is used as an applicable auto switch and a cylinder model is changed.

Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2

6 t Zinc chromated w Electroless nickel plated Black zinc chromated Accessory Accessory IN 2 Series ARJ310 Dimensions ARJ310-01 ARJ310F-01 Approx. 31 Approx. 56 Approx. 56 Approx. 35 32 22 M12 x 1 Panel fitting dimensions 12.5/Panel thickness: 4 or less Approx. 27 19 2 2 -5.5 Approx. 57.2 8.5 Approx. 82.5 15 Applicable tube O.D. 4, 6, 5/32, 1/4 Port size Rc, NPT 1/8 2 2 1 1 Pressure gauge

Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.

Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.

Pressure Source 2. Hold the product from the body side when handling. The tensile strength of the power cord is 49N, and pulling it with a greater force can cause failure. Warning 1.

Pressure Source 2. Hold the product from the body side when handling. The tensile strength of the power cord is 49N, and pulling it with a greater force can cause failure. Warning 1.

VGA VPA VPA3 VPA3 2 x Mounting hole Port size Rc (EXH port) Port size 2 x Rc (IN, OUT port) Port size Rc Model Mounting hole IN, OUT EXH A B C D E F G H J K L 3 8 1 2 3 4 VPA3145 71 3 4 8.5 85 14 52 55 93 32 87.4 36 71 80 3 4 VPA3165 82.6 1 4 8.5 1 110 17 68 75 118 45 113 36 71 95 1 1 4 1 1 1 1 4 1 2 VPA3185 118 13 2 132 14 80 95 140 52 140 41 81 105 2 1575

O 5/32 P 3/16 U 7/32 R 1/4 A 9/32 S 5/16 T 3/8 V 5/64 B 1/2 C 5/8 D 1 E 1 1/2 Y 3/4 F 2 W 3 D No Option Ports T Metering (1/32 1/8 orif.)

30 (n 4) 2 (n = 4, 8, 12, 16)*2 55 + 30 (n 4) 2 (n = 4, 8, 12, 16)*2 60 + 30 (n 4) 2 (n = 4, 8, 12, 16)*2 70 + 30 (n 4) 2 (n = 4, 8, 12, 16)*2 *2 When n is an odd number, a multiple of 4 that is larger than the odd number is to be used for the calculation. 39 Auto Switch Mounting C96N Series Minimum Stroke for Auto Switch Mounting Specific Product Precautions Working Principle Model

+ 0.77 (n: stations) Rc3/8 Rc1/2 Rc1/2 Rc3/4 22 Series VQ7-8 DIN Connector Type VV72-142 118 142 118 9 2n-Rc3/8, 1/2 67 20 Indicator light 14 34 9 (4-Rc1/8) Port P, R1, R2 for Rc3/4 only U side U side 18 Manual override 23 R4.5 R4.5 P= 56 60 (73) 60 (73) P= 56 B B B B B 14 42 18 13 13 A B SMC SMC SMC B B B A A A A A PA PA PA A B A B L1 L2 L1 L2 A B SMC PA A B PA L side R side L side R side

(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.

D-Z7m D-Z8m D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10

Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?

D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13

Put a flat washer (8 x 3.3) through a hexagon socket head screw (with spring washer, M3 x 0.5 x 5 l) and passing through the hole of a switch mounting bracket, then turning it lightly down to a mounting nut of switch. (2 locations) 5.

(For details, refer to page 4-4-11.) 4-4-6 7 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ300 Construction (A) 2 (A) 2 N.C.