SMC Corporation of America
Elite Part Number Search
Search Results "55-JSXFAF-10N-B"

A B 2-P C L L C A B A B LVA10 2-F B B K LVA60 LVA20 With flow rate adjustment With indicator (Max.

Supply NC output NO output Exhaust of NC exhaust of NO Pilot tor NC Pilot for NO P A B R s z Y P A B R1 R2 z Y P A B EA EB PA PB 1 2 4 3 5 12 1 4 Table 7.2 Typical port identitications M O N O S T A B L E A N D B I S T A B L E Spring returned valves are monostable. They have a defined prefened position to which they automatically retum.

Supply NC output NO output Exhaust of NC exhaust of NO Pilot tor NC Pilot for NO P A B R s z Y P A B R1 R2 z Y P A B EA EB PA PB 1 2 4 3 5 1 2 1 4 Table 7.2 Typical port identitications M O N O S T A B L E A N D B I S T A B L E Spring returned valves are monostable. They have a defined prefened position to which they automatically retum.

LVC B A B A B A PB Double acting N.C. N.O. Double acting LVA With flow rate adjustment PA PA N.C. B A PB B A Double acting LVH N.C. Double acting With bypass PA PA N.C. LVD PB B A B A Double acting N.C. Double acting With flow rate adjustment & bypass LVQ PA PA N.C. PB B A B A Double acting N.C. Double acting LQ1 With indicator PA N.C. B A LVN N.C.

L E T U B E OD 6 A P P L I C A B L E T U B E OD 6 Courtesy of Steven Engineering, Inc. !

SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.

Contents 20 MGP20-B-PS Set of nos. above @4, @5, @6, @7, #5, $4, $5 50 MGP50-B-PS Set of nos. @4, @5, @6, @7, above #5, #6, $4, $5 63 MGP63-B-PS 80 MGP80-B-PS Set of nos. @4, @5, @6, @7, above $4, $5 100 MGP100-B-PS 25 MGP25-B-PS 32 MGP32-B-PS 40 MGP40-B-PS *: Each seal kit includes the parts listed above.

Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5 7 42.5 6 20 47 13 47.5 13.5 44.5 10.5 52.5 18.5 46 12 50 16 49 15 32 55 17 5.5 17.5 52.5 14.5 60.5 22.5

Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5 7 42.5 6 20 47 13 47.5 13.5 44.5 10.5 52.5 18.5 46 12 50 16 49 15 32 55 17 5.5 17.5 52.5 14.5 60.5 22.5

A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5 7 42.5 6 20 47 13 47.5 13.5 44.5 10.5 52.5 18.5 46 12 50 16 49 15 32 55 17 5.5 17.5 52.5 14.5 60.5 22.5 54 16 58 20 57 19 40 79 39 79.5 39.5 76.5 36.5 84.5 44.5 78 38 82 42 81 41 50 82 44 82.5 44.5 79.5 41.5 87.5 49.5 81 43 85 47 84 46 63 85.5 41.5 86 42 83 39 91 47 84.5 40.5 88.5 44.5 87.5 43.5 Operating Range Auto switch model

7 o i Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Component Parts: Standard Piping No. Description No.

High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when workpiece is vacuumed. Min.B: Maximum pressure value when workpiece is not vacuumed.

J M N 10-/21-AR20-B 10-/21-AR25-B 10-/21-AR30-B 10-/21-AR40-B 10-/21-AR40-06-B 10-/21-AR50-B 10-/21-AR60-B 2 Note 2) 1/8, 1/4 28.5 1/8 20.5 40 11 67.4 44 26.5 65.5 M28 x 1 30 28.5 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 1/4, 3/8 0 27.5 1/8 21.3 53 9.8 71.9 44 28 64.5 M32 x 1.5 30 27.5 34 43.9 5.4 15.4 55 2.3 25.7 32.5 16 6 1/4, 3/8 3.5 29.4 1/8 24.8 53 10.5 85.6 44 30.7 66.4 M38 x 1.5 41

A 35.5 44.5 52.5 76.5 79.5 83 A 37 46 54 78 81 84.5 B 5.5 12 16 38 43 40.5 A 41 50 58 82 85 88.5 B 9.5 16 20 42 47 44.5 A 38 47 55 79 82 85.5 B 6.5 13 17 39 44 41.5 B 7 13.5 17.5 39.5 44.5 42 A 43.5 52.5 60.5 84.5 87.5 91 B 12 18.5 22.5 44.5 49.5 47 B 4.5 10.5 14.5 36.5 41.5 39 CE1 CE1 12 20 32 40 50 63 CE2 ML2B Note) Adjust the auto switch after confirming the operating conditions in the

CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]

center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.

20 0.19 b 0.3 37 30 0.39 b 0.48 19 40 0.79 b 0.8 1.3 1 Compared with existing products (AFFmC, AMmC, and AMDmC series) 2 Compared with existing products (AMFmC series) 50 1.25 b 1.3 4 60 1.50 b 2.0 25 Color-identifiable elements This eliminates the accumulation of condensate.

Byte 1 DY#B (Unit 2) Output 0 to 7 Byte 2 AXA channel 1 Hi byte Byte 2 Output 0 to 7 (Unit 0) Byte 3 Lo byte Byte 3 Output 8 to 15 SEN7 (Unit 5) Byte 4 DX#B (Unit 3) Input 0 to 7 Byte 4 Output 16 to 23 Byte 5 Input 0 to 7 Byte 5 Output 24 to 31 DX#D (Unit 4) Byte 6 Input 8 to 15 Byte 6 Byte 7 Padding data Byte 7 Total 8 bytes Total 6 bytes 1: Refer to "Parameter Setting" (page 55) for setting

43 10 31 19 15 36.5 24.5 D-A90V 5 25.5 26.5 13.5 14.5 A B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.