Made to Order: Standard, Body Size: 1/4, Handle-operated Type, Pressure Increase Ratio Twice, Thread Type: NPT - Made to Order, Port Size: 1/4, Option: None, Semi-standard: Display Units for Product Nameplate & Pressure Gauge: psi
Made to Order: Standard, Body Size: 1/4, Handle-operated Type, Pressure Increase Ratio Twice, Thread Type: NPT - Made to Order, Port Size: 1/4, Option: G [Pressure Gauge (2 pcs.)], Semi-standard: Display Units for Product Nameplate & Pressure Gauge: psi
Made to Order: Standard, Body Size: 1/4, Handle-operated Type, Pressure Increase Ratio Twice, Thread Type: NPT - Made to Order, Port Size: 1/4, Option: Silencer, Semi-standard: Display Units for Product Nameplate & Pressure Gauge: psi
Made to Order: 56 [CE Explosion-proof Directive (ATEX): Category 3GD], Body Size: 1/4, Handle-operated Type, Pressure Increase Ratio Twice, Thread Type: F [G (PF)], Port Size: 1/4, Option: -, Semi-standard: -
The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional power
Body Size: 1/4, Pressure Increase Ratio: 2 Times, Option: None
Body Size: 1/4, Pressure Increase Ratio: 2 Times, Option: OUT Side Pressure Gauge
Body Size: 10A (1/4, Pressure Increase Ratio: 2 Times), Option: G (OUT Side Pressure Gauge)
Body Size: 10A (1/4, Pressure Increase Ratio: 2 Times), Option: None
The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional
Made to Order: 56 [CE Explosion-proof Directive (ATEX): Category 3GD], Body Size: 10A (1/4, Handle-operated Type, Pressure Increase Ratio Twice), Thread Type: Rc (PT), Port Size: 02 (1/4)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 7 (240VAC 50/60HZ), Lead Wire: G (Grommet), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 7 (240VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: F (G), Voltage: 7 (240VAC 50/60HZ), Lead Wire: G (Grommet), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: F (G), Voltage: 4 (220VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.2 Solenoid, Body Size: 6 (25A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: T (NPTF), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)
Applicable model D7 L26 L28 AS-10A AS1002FS 9.2 4 18.7 AS-20A AS2002FS 9.4 8.8 20.4 AS-25A AS2052FS 11.4 6.3 27 AS-30A AS3002FS 11.8 5.9 32.1 Part no. Applicable model D7 L27 L28 AS-10A1 AS1002FS 9.2 4.5 18.7 AS-20A1 AS2002FS 9.4 9.3 20.4 AS-25A1 AS2052FS 11.4 7.1 27 AS-30A1 AS3002FS 11.8 6.4 32.1 2 x D7 2 x D7 L26 L27 L28 L28 The AS4002FS can be mounted without the adapter.
AN LECPA3 (Pulse input type) NPN AP PNP 11LEFS 1 For details about controller/driver and compatible motor, refer to the compatible controller/driver below. 2 Not applicable to CE. 3 When pulse signals are open collector, order the current limiting resistor (LEC-PA-R-) on page 596 separately. 11LEJS 25A!