R R L1 L3 L2 PE TB N PE L TB PRR ILS THR ILS MC THR MC MC PRR CM C01 MC OLR OLP1 CM OLP2 C11 FM PRS MOV P M C11 FM PRS M P IDF55E-30 IDF75E-30 GFCI R GFCI R GFCI GFCI TB TB PRR PRR THR THR CM CM MC2 MC2 FM FM THP THS THP MC1 MC1 MC2 MC2 PRS1 PRS1 P P PRS2 THR PRR PRS2 THR PRR P P M M CM PRS OLR FM PRS1 PRR MC PRS2 TB MC1 ILS GFCI MC2 THR MOV C01 CM THS OLP1 C11 FM THP
IDX-OM-W025-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) Please read this manual prior of using the air dryer. Keep the manual readily available for reference. To Customers Thanks for purchasing SMC Refrigerated Air Dryer.
(110) 519 IDFA75E 900 (968) IDFA Series 6-3 6 2 IDX-OM-W032 6 6-4 IDFA22E, 37E GFCI R GFGI For Option R L N PE TB ILS V For Option V EVD EDV CM OLR PE C01 C11 PE FM PRS P IDFA55E, 75E GFCI R L N PE CM FM () MC C01 CM C11 FM1 PRS PRS1 PRS2 ILS THR OLR 1 THP TB GFCI EDV C01 P PE P C11 FOR OPTION V V IDFA Series 6-4 6 3 IDX-OM-W032 6 6-5 IDF55E,IDF75E IDFA22E,37E IDFA55E
3/h) (273 m 3/h) (384 m 3/h) (510 m 3/h) Air FlowRate (ANR)(Note 1) 120SCFM 173SCFM 258SCFM 353SCFM At Expected Outlet Press.Dew Point of 45 oF (7.2 oC) (205 m 3/h) (294 m 3/h) (438 m 3/h) (600 m 3/h) 130SCFM 181SCFM 297SCFM 406SCFM At Expected Outlet Press.Dew Point of 50 oF (10 oC) (221 m 3/h) (308 m 3/h) (504 m 3/h) (690 m 3/h) Operating Pressure 100psig (0.7MPa) Condition Rated Inlet
IDX-OM-W014-C / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 ) *1) ISO 4414
C D E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110] [250] [50] [13] [5002] [75] [7001] [526] [5195] [36] 35.4 38.1 IDFB75E 2 [900] [968] IDFB Series 6-3 6-2 IDX-OM-W035 6 6-4 IDFB22E-11 IDFB22E/37E-23 R GFCI GFCI R GFCI R GFCI L N PE R TB1 PE N L 1 2 TB1 1 2 1 2 S MC S C1 IDFB22E
IDX-OM-W031-B PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA22E-23C,K,L,R,T,V IDFA37E-23C,K,L,R,T,V IDFA55E-23C,L,R,T,V IDFA75E-23C,L,R,T,V This manual is intended to explain the installation and operation of the product.
PSE56-C01 24 B PSE56-A2 A B Model 8.2 12 9.2 12.2 15.5 9.5 A PSE56-01 PSE56-02 PSE56-N01 PSE56-N02 PSE56-C01 PSE56-A2 PSE56-B2 R 1/8 R 1/4 NPT 1/8 NPT 1/4 Rc 1/8 URJ 1/4 TSJ 1/4 24 B PSE56-B2 A 24 B 16-3-28 7 Series PSE Specific Product Precautions 1 Be sure to read before handling. Pressure Sensor Handling Air Supply Warning Warning ZSE ISE 1.
For positive pressure 80 ISE 02 N M For vacuum/ compound pressure 80 ZSE 02 N M Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English
IDX-OM-W013-C PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) This manual is intended to explain the installation and operation of the product.
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Rc1/8, Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Operation Manual: Operation Manual, Calibration Certificate
IDX-OM-W016-D Operation Manual Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V IDFA6E-23-A,C,K,L,R,T,V IDFA8E-23-A,C,K,L,R,T,V IDFA11E-23-A,C,K,L,R,T,V IDFA15E1-23-A,C,K,L,R,T,V Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
"M" in the part number means that the units cannot be changed.
Program end 500[r/min] 200[ms] 300[ms] 600[10STMm] 300[10STMm] 700[r/min] 700[10STMm] 300[10STMm] a) b) c) d) e) f) a) Incremental move command (600 10STM m) 900 10STM m (a) MOVI (600) +e) TRIPI (300)) b) 300 10STM m d) Incremental continuous move command (700 10STM m) Forward rotation 0r/min Servo motor speed ON Program output 1 (OUT1) OFF c) f) 13 38 13.
IDX-OM-W093-B / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC *1) JIS B8370 *2) ISO4414 *1) ISO4414Pneumatic fluid power Recommendations for the application
/80/90 Series 9-1 IDX-OM-W094 L 10 L L 10.1 0 () 10.2 ADH4000-04 ADH4000-04 ADH-E400 ADH-E400 N.O. 1.6MPa 0.051.6MPa 0.024m 3/h 0.7MPa IDFA60/70/80/90 Series 10-1 IDX-OM-W094 L 10.3 Rc1/225 30 5 IDFA60 2722IDFA70,IDFA80,IDFA90 22 IDFA60 (IDFA70/80/90) 1) 2830Nm 2) 10.4 1 1 IDFA60/70/80/90 Series 10-2 IDX-OM-W094 R 11 R R (GFCI) 11.1 11.2 IDFA60-23-R IDFA70-23-R IDFA80
IDX-OM-V022-H Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
IDX-OM-V020 Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA60-23-A,C,L,R,T,V IDFA70-23-A,C,L,R,T,V IDFA80-23-A,C,L,R,T,V IDFA90-23-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
ADH-E400 1.6MPa 0.051.6MPa 0.024m 3/h 0.7MPa IDFC60/70/80/90 Series 9-1 IDX-OM-W095 L 9.3 Rc1/225 30 5 IDFC60 2722IDFC70,IDFC80,IDFC90 22 IDFC60 (IDFC70/80/90) 1) 2830Nm 2) 9.4 1 1 IDFC60/70/80/90 Series 9-2 IDX-OM-W095 R 10 R R (GFCI) 10.1 10.2 IDFC60-23-R IDFC70-23-R IDFC80-23-R IDFC90-23-R (A) 10 15 20 30 (mA) 30 IDFC60/70/80/90 Series 10-1 IDX-OM-W095 R 10.3 M3.5