Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.
Refer to L dimensions Enter a number from the DIN rail dimension table below. d L 8 (10) D (24) (35) 5.5 A L Rail mounting hole pitch: 12.5 0 98 24.8 5 160.5 40.6 7 185.5 46.9 1 110.5 28 6 173 43.8 8 198 50.1 2 123 31.1 9 210.5 53.3 3 135.5 34.3 4 148 37.4 No.
(For type 20 manifold) SYJ5 10 2 1 3 5 L M5 Body ported 10 SYJ5 4 2 5 3 L CE-compliant Base mounted Nil Q CE-compliant Note) AC-type models that are CE-compliant have DIN terminals only.
Refer to page 642 for the lead wire length of L and M plug connectors. Refer to page 645 for the connector assembly with cover for L and M plug connectors. 616 3 Port Pilot Solenoid Valve 10-SYJ500 Construction r w t q y e r w t q y e N.C. N.O.
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -
ZSE20C(F)-L is CE and RoHS compliant, with an IP65 enclosure rating.
ZSE20C(F)-L is CE and RoHS compliant, with an IP65 enclosure rating.
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire,
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm.
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported)
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported)
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L
Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended