ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported)
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L
Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended
ZSE20C(F) is UL/CSA, CE and RoHS compliant.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
And the ISE/ZSE20C series (for general purpose fluids) catalog can be found here.
ZSE20C: ZSE20C, Rated Vaccum Range: -100 to 100 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -
ZSE20C: ZSE20C, Rated Vaccum Range: -100 to 100 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -
ZSE20C: ZSE20C, Rated Vaccum Range: -100 to 100 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -
ZSE20C: ZSE20C, Rated Vaccum Range: -100 to 100 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -