50 38 B A R2 R1 P 2-1/8 13 13 Mounting hole 2-6.5 Indicator light 34 34 (P , A, B) 3-1/4, 3/8 42.5 42.5 G1/2 (Cable 8 to 10) Bottom ported drawing 137.5 SMC 125.5 93 14 (A, B port) 25 (X port) 12 Y 5 3 37 25 22 14 1 25 25 X (PE) port 1/8 A, B port 2-/4, 3/8 9 1/8 R1, R2 port 2-3/8 P port 1/4, 3/8 Y(PE) port 2 position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D 3 position closed
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Connector Type: S (M12 connector type), Bracket: A5 (Bracket E for M12 Connector Type)
) 112 93 12 Y 25 (14 port) PE port 5 3 37 25 22 14 1 25 25 9 1/8 12 port 3/8-2 port 3, 5 port 1/4, 3/8 1 port 14 port 1/8 1/4, 3/8-2 port 2, 4 port EVS7-6-FG-D-M0 EVS7-6-F G-D-M0 H J I 186 196 89 89 13 (4 port) 50 50 13 (2 port) 13 (4 port) 50 50 13 (2 port) B A B A 50 62 50 62 38 14 38 12 14 12 Manual override Manual override P R1 R2 P R1 R2 Indicator light 2-6.5 mounting hole 42.5 42.5
Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
This is a legacy product, and replaced byISE20B-Y-P-C6L-WA2, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .33733 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.
This is a legacy product, and replaced byZSE20F-P-C6L-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 1E, ZSE30 OTHER SIZE RATING, .29394 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment
For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)