7.5 M5 x 0.8 (P, R port) 17.5 23 L plug connector (L): 10-SYJ34M-L-M5 M plug connector (M): 10-SYJ34M-M-M5 M8 connector (WO): 10-SYJ34M-WO-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.5 [60.7] 48.7 [50.9] 57.6 50.2 43.7 R P R P R P 10 8.6 10 8.6 10 8.6 23 23 23 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to page 646 for dimensions

(F) kPa P ISE20B psi ZSE20B(F) [F 1] OUT1 32 OFF ONOFF ISE20B 0.500 MPa ZSE20B -50.5 kPa ZSE20BF50.0 kPa ISE20B0.050 MPa ZSE20B 5.1 kPa ZSE20BF5.0 kPa 1.5ms OUT1 ON OUT1 OFF -29No.PS-OMU0005CN-C [F 2] OUT2 35 [F 1]OUT1 [F 3] 37 0 ms [F 4] 38 [F 5] FUNC 40 [F 6] 42 0% [F10] 43 std() [F11] 49 1000 [F80] 50 OFF [F81] 51 OFF [F82] 53 A [F90] 54 OFF [F96] 56 [F97] 57 OFF

: A24 Symbol: A25 Symbol: A26 Symbol: A27 DA MM DA MM MM MM 30 30 H AL A H L A H AL H AL L K LB K Symbol: A28 Symbol: A29 Symbol: A30 30 30 30 MM DA MM W L W H L A H A AL H A T T MM 47 CP96N/C96N Series Made to Order Common Specifications Please contact SMC for detailed dimensions, specifications, and delivery times.

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

The ZSE20B(F)-S is a digital vacuum sensor with all standard features of the ZSE20B(F), while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.

The ZSE20B(F)-S is a digital vacuum sensor with all standard features of the ZSE20B(F), while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.

Bracket mounting inserts found on the standard ZSE20B(F) are omitted as well.  25A-ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: -

This is a legacy product, and replaced byISE20B-R-M5-WA2 ISE40/50/60 PRESSURE SWITCH. SWITCH. INSTRUMENTATION. ISE40/50/60 M5 PT VERSION. .36008 lb. AA.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)