SMC Corporation of America
Elite Part Number Search
Search Results "ZM103H-J5LOZ-X111"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Nozzle Diameter: ø1.0, Body Style: Manifold w/Common SUP Valve, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Vacuum

Nozzle Diameter: ø1.0, Body Style: Manifold w/Common SUP Valve, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve+Release Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Style,

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E15 (1 Output w/o Analog Output, 200° Setting), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E15 (1 Output w/o Analog Output, 200° Setting), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM GENERATOR,HIGH PRESS/DC, VACUUM SERIES, ZM VACUUM SYSTEM, CC, ZM NOZZLE SIZE 1.0, .61729 lb

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

Doc no. LEC*-OMY0102-A NN32462501 PRODUCT NAME AC Servo Motor Driver (Network card type MODEL/ Series LECSN-T Series LECSN2-T Series / Driver 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes

Valve), Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E14 (1 Output w/o Analog Output, 3 Rotation), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

Supply Valve+Release Valve), Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Valve Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E15 (1 Output w/o Analog Output, 200° Setting), Vacuum Switch Electrical Entry: CL (Connector Lead Wire Length 3.0m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

, Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Type), Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Valve: Without Valve, Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Valve: Without Valve, Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

: 5 (24VDC), Electrical Entry: G (Grommet Type w/0.3m Lead Wire), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E14 (1 Output w/o Analog Output, 3 Rotation), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: E14 (1 Output w/o Analog Output, 3 Rotation), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111