Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread

Magnet: Built-in Magnet, Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 15 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Magnet: Built-in Magnet, Bore Size: 6, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 15mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Magnet: Built-in, Mounting: Basic, Bore Size: Ø16 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 1 pc., Option: -

Magnet: Built-in, Mounting: Flange, Bore Size: Ø6 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 1 pc., Option: -

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread

This is a legacy product, and replaced byCDJP2B16-15D

This is a legacy product, and replaced byCDJP2B6-15D

This is a legacy product, and replaced byCDJP2B6-15D-A93

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø6 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: A93, Lead

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: A93, Lead

The ZCUK series is a non-rotating free mount cylinder for vacuum applications. The ZCUK was created by providing a vacuum passage in the rod of the CUK cylinder to enable a vacuum pad to be installed on the end of the rod. A guide is provided as standard equipment. Vacuum pads are available with pad diameters of ø2 to ø50. Cap or rod piping is available to the rod side. Series ZCUK is available