SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-K15L-FB-01"

+.002 1.88 2.56 3.50 .75 NCA1-P325 1.25 0 0.75 +.004 .53 .78 .62 -.01 +.002 Courtesy of Steven Engineering, Inc. !

VQ2000FPG-FB 01 1 station 0.8 to 1.0 Nm 16 16 stations Note) It is the tightening torque for mounting a bracket for the perfect block.

Bracket Assembly Stations 01 Part no. VQ1000FPG-FB Tightening torque 0.16 to 0.18 lbfft 1 station (0.22 to 0.25 Nm) 16 16 stations VVQ1000-FPG-06 6-station manifold VQ1000-FPG-C4M5-D, 3 sets VQ1000-FPG-C6M5-D, 3 sets Note) This torque is used to mount the bracket on the double check block.

Note 2) Specify wiring type of each station on the manifold In the case of the 16-output SI unit Symbol 01 Stations Note 1 station specification sheet. Double wiring Note 1) 08 01 8 stations 1 station Specified layout Note 2) (Available up to 16 solenoids) Note 1) Indicate the sizes on the manifold specification sheet in the case of CM.

Tightening torque (Nm) VQZ1000-FB-M VQZ1000-FB-R VQZ2000-FB VQZ3000-FB Metal seal 0.2 to 0.26 VQZ1000 Rubber seal Note) Other 0.25 to 0.35 0.25 to 0.35 VQZ2000 VQZ3000 Note) For the special voltages, please consult with SMC.

L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-MDIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR251001 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03

M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX

CX Dimensions Dimensions DM5 x 0.8 Relief port (Vacuum port) -X 20Data FB B + Stroke A + Stroke 5 10 FB B + Stroke A B Bore size (mm) FB A + Stroke 50 stroke or less 66 67.5 109 109 117.5 117.5 121 141 51 stroke or more 97.5 99 114 114 129 129 148 166 20 25 32 40 50 63 80 100 19 20 22 22 23 23 24 29 Other dimensions are the same as standard type. 66 67.5 71.5 78 83 88 102.5 120 A Over 30

-06 AS2200-01 70% 100 50 10% 30% 50% 0 CM2 25 200 150 AS2201F -01-06 AS2200-01 100 50 0 SV100 ANA1 -C08 T0604 CM2 32 200 150 AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end (mm/s) Applicable related components For details regarding different conditions

They are the New FB option in the Edit Menu and the AddFB option when connecting two blocks. 4.4.1 New FB To use the New FB option, proceed to the Edit Menu (Section 3.4.1) with the ESC key. Scroll to the New FB option and press OK. Scroll to the desired Function Block and press OK to create a New FB.

-04-12 AS1301FG-M5-23 AS2301FG-01-23 AS1301FG-M5-04 AS2301FG-01-04 -02-04 AS1301FG-M5-06 AS2301FG-01-06 -02-06 AS3301FG-02-06 -03-06 AS2301FG-01-08 -02-08 AS3301FG-02-08 -03-08 AS1211FG-M5-23 AS2211FG-01-23 AS1211FG-M5-04 AS2211FG-01-04 -02-04 AS1211FG-M5-06 AS2211FG-01-06 -02-06 AS3211FG-02-06 -03-06 AS2211FG-01-08 -02-08 AS3211FG-02-08 -03-08 AS2211FG-01-10 -02-10 AS3211FG-02-10 -03-10

Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port

Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: w/o Pressure Sensor, Air Pressure Supply, P Port: w/o Fitting, M3 x

Note 2) Specify wiring type of each station on the manifold In the case of the 16-output SI unit Symbol 01 Stations Note 1 station specification sheet. Double wiring Note 1) 08 01 8 stations 1 station Specified layout Note 2) (Available up to 16 solenoids) Note 1) Indicate the sizes on the manifold specification sheet in the case of CM.

Note 1) 1 station 01 16 stations Note) Number of terminals 16 Note 2) Refer to page 2-4216 for details.

-01-04-X214 AS1201FPQ-M5-04-X214 Elbow type/Brass (throttle valve) AS2201FPQ-01-06-X214 AS1201FPQ-M5-06-X214 CY1S With clean One-touch fitting AS2201FPQ-01-08-X214 AS2201FPG-01-04-X214 AS1201FPG-M5-04-X214 Elbow type/ Stainless steel 304 (throttle valve) CY1L AS2201FPG-01-06-X214 AS1201FPG-M5-06-X214 AS2201FPG-01-08-X214 CY1H Note 1) Refer to Back Page 10 (How to Use Clean Series) for the