Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 110 VAC, Electrical Entry: DIN Termianl w/Light, w/Surge Voltage Suppressor, Special Electrical Entry: -, Spacer: -
Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 24 VDC, Electrical Entry: Conduit w/Surge Voltage Suppressor, Special Electrical Entry: -, Spacer: -
Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 24 VDC, Electrical Entry: DIN Termianl w/Light, w/Surge Voltage Suppressor, Special Electrical Entry: 180°, Spacer: -
Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 24 VDC, Electrical Entry: Grommet, Special Electrical Entry: 90°, Spacer: -
Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 24 VDC, Electrical Entry: DIN Terminal w/Surge Voltage Suppressor, Special Electrical Entry: -, Spacer: -
Model: Size 2, Orifice Size: ø4.5, Fitting Size: 1/4, Fitting Type: NPT Female Thread, Voltage: 24 VDC, Electrical Entry: Grommet, Special Electrical Entry: -, Spacer: -
XSA1 XSA1R-8-1 XSA2 XSA2R-8-1 XSA3 *1 Not CE-compliant For the special option below, refer to page 7. Special electrical entry direction 2
Twist Selector (2 position)/VM220-02-34R, B, G, Y/VM230-02-34R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 32N F.O.F. 0.5MPa supply 90 T.T. 3.5-23 VM200 Series VM200 Key Selector (2 position)/VM220-02-36, VM230-02-36 Panel mounted hole SlA JIS Symbol 2 port VlA 3 port SlA VlA 32N F.O.F. 0.5MPa supply VM/VR Key can be removed in on and off positions. 90 T.T.
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control equipment d3 3d1 3d3 Flow control valve d2 Flow meter Air supply Filter Shut off valve 10d2 3d1 3d2 10d3 10d1 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the upstream side Pipe for measuring pressure in the downstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control equipment d3 3d1 Flow control valve 3d3 d2 Flow meter Shut off valve Filter Air supply 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control equipment d3 3d1 Flow control valve 3d3 d2 Flow meter Shut off valve Filter Air supply 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 d2 Flow control valve Shut off valve Filter Flow meter Air supply 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control equipment d3 3d1 Flow control valve 3d3 d2 Flow meter Shut off valve Filter Air supply 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure converter Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 Flow control valve 3d3 d2 Air Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 supply Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig.
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure in the upstream side Equipment for test Pipe for measuring pressure in the downstream side