Example: SS3YJ3-20-03.1 set (Manifold base) SYJ312-5LZ-M3.2 sets (Valve) SYJ300-10-1A.1 set (Blanking plate assembly) SS3YJ3-42R-03-C4 .1 set (Manifold base) SYJ314R-5G.2 sets (Valve) SYJ300-10-2A. 1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
(Manifold base) VZ110-5LZ-M52 pcs. (Valve) DXT170-25-1A1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
(Manifold base) SYJ312-5LZ-M3 .2 pcs. (Valve) SYJ300-10-1A .1 pc. (Blank plate ass'y) SS3YJ3-42R-03-C4 .1 pc. (Manifold base) SYJ314R-5G .2 pcs. (Valve) SYJ300-10-2A .1 pc.
Example: SS3YJ3-20-03.1 set (Manifold base) SYJ312-5LZ-M3.2 sets (Valve) SYJ300-10-1A.1 set (Blanking plate assembly) SS3YJ3-42R-03-C4 .1 set (Manifold base) SYJ314R-5G.2 sets (Valve) SYJ300-10-2A. 1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
(Example) 10-SS3YJ3-20-03 . 1 set (manifold base) 10-SS3YJ3-42-03-C4 . 1 set (manifold base) SYJ300-10-7A . 1 set (blanking plate assembly) 10-SYJ312M-5LZ-M3 . 2 sets (valve) 10-SYJ314M-5G . 2 sets (valve) SYJ300-10-7A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
MVGQM12-30-Z73-B 1 SFJ3130-5LZ-MA 1 For the applicable auto switch model, refer to page 10-16-5. Auto switches are shipped together, (but not assembled). Lead wire length for auto switch Cylinder stroke (mm) Refer to Standard Stroke on page 10-16-5.
(Manifold base) SYJ5140-5LZ 1 pc. (Valve) SYJ5240-5LZ 1 pc. (Valve) SYJ5000-21-1A 1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Use manifold specification sheet. 34 Series SYJ5000 Flat Ribbon Cable Manifold Multiple valve wiring is simplified through the use of the flat cable connector.
(Manifold base) SYJ7140-5LZ 1 pc. (Valve) SYJ7240-5LZ 1 pc. (Valve) SYJ7000-21-1A 1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
By combining the reference points of these two pieces of data, you will be able to see the CAD data of the SY5140-5LZ-02.
Valve Type: Double Acting, Bellows Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Right Flange Surface, Temperature: 5 to 60°C, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal
output NPN or PNP open collector (same as switch output) Illuminates up when output is ON OUT1: Green; OUT2: Red 1 sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode Note 6): 3-digit fixed 12 to 24 VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) 1000 VAC for 1 min. between external terminal and case 50M
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLAV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLAV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLAV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLAV-50-2 38.2 10.2 3.6 3.6 M5 M5 XLAV-63-2 43.8 12 4 2 Rc1/8 M5 XLAV-80-2 59.8 12 4
A XLAV: Air operated, With solenoid valve J N M Port 1(P) K L Port 3(R) Solenoid valve [mm] Model J K L M N XLAV-16-2 41 18.5 8.5 2.7 3 XLAV-25-2 45.5 22.5 8.5 2.7 3 XLAV-40-2 54.5 35 8.5 2.7 3 XLAV-50-2 61 39.5 8.5 2.7 3 XLAV-63-2 80.5 44 12 4 2 XLAV-80-2 90.5 60 12 4 2 6 Aluminum High Vacuum Angle Valve Double Acting, Bellows Seal RoHS XLC Series How to Order q w e r t y u XLC 2 M9N 16
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen.
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen.
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen.
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 80, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen.