Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150,
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: -, Flange Type: -, Port Direction: -, Temperature: -, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Valve Type: Angle Type, Double Acting, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 150°C, Suffix: -, Auto Switch: -, Lead Wire: -, Number: -, Seal Material: -, Seal Replacement: -
Flange Size: -, Flange Type: -, Port Direction: -, Temperature: -, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Variation: A (Normally Closed, Bellows Seal), Flange Size: 16, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 25, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 40, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 40, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9B (M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal), Lead Wire: 0.5m (Or None in the Case of No Switch), Number of Switches, Mounting Position: A (2 pcs, Valve
Variation: A (Normally Closed, Bellows Seal), Flange Size: 16, Indicator, Actuator Port Direction: G (w/Indicator, Actuator Port Direction on Rear Flange Surface), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 25, Indicator, Actuator Port Direction: G (w/Indicator, Actuator Port Direction on Rear Flange Surface), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 40, Indicator, Actuator Port Direction: G (w/Indicator, Actuator Port Direction on Rear Flange Surface), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9// (w/o Auto Switch, w/Built-in Magnet)
Variation: A (Normally Closed, Bellows Seal), Flange Size: 16, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: H0 (5 to 150°C, w/o Heater), Auto Switch: w/o Auto Switch, w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Switch), Number of Switches, Mounting Position: w/o Auto Switch, X: X (Indicates
Variation: A (Normally Closed, Bellows Seal), Flange Size: 25, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Switch), Number of Switches, Mounting Position: w/o Auto Switch, X: X (Indicates a
Variation: Normally Closed, Bellows Seal, Flange Size: 16, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/Built-in Magnet, Lead Wire: -, Number of Switches, Mounting Position: -, X: -, Body Surface Treatment: -, Seal Material: -, Seal & Leakage Change: -
Variation: Normally Closed, Bellows Seal, Flange Size: 25, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/Built-in Magnet, Lead Wire: -, Number of Switches, Mounting Position: -, X: -, Body Surface Treatment: -, Seal Material: -, Seal & Leakage Change: -
Variation: Normally Closed, Bellows Seal, Flange Size: 40, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/Built-in Magnet, Lead Wire: -, Number of Switches, Mounting Position: -, X: -, Body Surface Treatment: -, Seal Material: -, Seal & Leakage Change: -
Variation: Normally Closed, Bellows Seal, Flange Size: 40, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Switch), Number of Switches, Mounting Position: 2 pcs, Valve Open/Closed, X
Variation: Normally Closed, Bellows Seal, Flange Size: 16, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Rear Flange Surface, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/Built-in Magnet, Lead Wire: -, Number of Switches, Mounting Position: -, X: -, Body Surface Treatment: -, Seal Material: -, Seal & Leakage Change
Variation: Normally Closed, Bellows Seal, Flange Size: 25, Indicator, Actuator Port Direction: w/Indicator, Actuator Port Direction on Rear Flange Surface, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: w/o Auto Switch, w/Built-in Magnet, Lead Wire: -, Number of Switches, Mounting Position: -, X: -, Body Surface Treatment: -, Seal Material: -, Seal & Leakage Change