SY5l3 0 1l-lll1-ll-Wl-V02l (Top ported) Plug F (Max. 3) For "F" marking (Thread type)
F E E F B C Cross interface E: 4-Rc E A F: Without thread D Model Port size A B C D Applicable model Y14-M5 M5 23 16 14 25 AC10 Y24-01 1/8 40 40 22 40 AC20 Y24-02 1/4 Y34-01 1/8 49 43 28 48 AC25, AC30 Y34-02 1/4 Y44-02 1/4 60 48 36 54 AC40 Y44-03 3/8 Cautions in Mounting When mounting a cross interface directly on the IN side of the lubricator, be sure to use a series AKM check valve between
, N9 P R2 R1 28.3 1.6 18 27.2 1.6 (PE port) 1/8 (P, R1, R2 port) B A 17 One-touch fitting (A, B port) (4.9) 36 Applicable tubing O.D.: 6, 1/4" : 8, 5/16" (3.6) L plug connector (L): SYJ7120-L-01 (-F) M plug connector (M): SYJ7120-M-01 (-F) M8 connector (WO): SYJ7120-WO-01 (-F) DIN terminal (D): SYJ7120-D-01 (-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 65 31.5 [38.5]
VX2121-00 VX2221-00 VX2321-00 VX2131-00 VX2231-00 VX2331-00 VX2241-00 VX2341-00 VX2113-00 VX2123-00 VX2223-00 VX2323-00 VX2133-00 VX2233-00 VX2333-00 VX2243-00 VX2343-00 2 2 0.17 4.1 4.1 0.17 3 3 0.33 7.9 7.9 0.33 3.0 3.0 4.5 4.5 0.61 15 15 0.61 6 6 1.10 26 26 1.10 Refer to Glossary of Terms on front matter 10 for details on the max. operating pressure differential and the max. system pressure
port Regulating port VQC P A1 B1 P port A port (P controlled type, A port regulation) B port (P controlled type, B port regulation) 00 M1 Pressure gauge (G15-10-01) Plug (M-5P) VQZ SQ ARBY7000-00--2 ARBY7000-M1--2 VFS VFR VQ7 + + Note) ARBY is not CE-compliant.
Application No. of ports 3 port 3 port VM130-01-00 VM131-01-00 VM132-M5-00 VM133-M5-00 Actuator Basic type Polyacetal roller Hard steel roller Mechanical operation Manual operation Roller lever VM130-01-01 VM131-01-01S VM133-M5-01 VM133-M5-01S Directional Control Equipment Polyacetal roller One way roller lever VM131-01-02 VM131-01-02S VM133-M5-02 VM133-M5-02S Hard steel roller VM-08B
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
VV307 01 F V100 Mounting bracket Thread type SY VT307 manifold Nil F N T Rc G NPT NPTF SYJ Manifold valve can be easily converted from N.C.
(mm) Model Double Branch "Y" KGUD 4 6 8 10 12 KGH04-00 Applicable tubing O.D. (mm) KGH06-00 Connection threads Model KGH08-00 KGH10-00 KGUD04-01 R 1/8 4 KGH12-00 -02 R 1/4 Bulkhead Union KGE KGUD06-01 R 1/8 6 -02 R 1/4 Applicable tubing O.D.
24.5 15.2 13.7 18.5 25.6/17.7 5/32 KQU03-00 10.4 34 18 10.4 9.7 16 3 10 KQU10-00 18.5 48 27.5 18.5 16.1 21 40/28.4 3/16 KQU05-00 11.4 36.5 20.5 11.4 10.6 16.5 3.5 12 KQU12-00 20.9 51 30 20.9 18.1 22 57.4/45.4 1/4 KQU07-00 13.2 38 21.5 13.2 12 17 4.6 5/16 KQU09-00 15.2 42.5 24.5 15.2 13.7 18.5 6 D I F F E R E N T D I A.
Linearity (77F) 0.15% F .S. Repeatability (77F) 0.6% F .S. 0.5% F .S.
-F VFA3130-01 2 1 8 3 VFA3430-01-X1 5 Body ported Base mounted VFA3122-02-F VFA3130-02 2 1 4 3 VFA3430-02-X1 5 1 8 VFA3140-02 2 1 4 (2) 3 VFA3440-02-X1 5 VFA3140-03 2 3 8 3 VFA3440-03-X1 5 Note 1) Port size of the exhaust ports on body ported type are all 1/8.
type B port regulated) B1 B1 Pressure gauge connection port Pressure gauge connection port Pressure gauge (G15-10-01) 00 Pressure gauge (G15-10-01) [for odd number stations] 05 Plug (M-5P) M1 Pressure gauge (G15-10-01) [for even number stations] 06 Plug (M-5P) M1 Note) Note that for series ARBY3000 with pressure gauge, part numbers differ for odd number and even number stations to prevent
Symbol AKM A 00 30 01 q e w Check valve Symbol Description Nq Body size 20 30 40 A Nil Rc N NPT F G + Nw Pipe thread type D 01 1/8 02 1/4 03 3/8 Ne By-pass port size Model By-pass port size A B C D E Applicable model Specifications By-pass port size for redirecting air flow AKM2000-A 1/8, 1/4 40 28 11 40 11 AC20-B, AC20A-B Model Effective area [mm2] AKM2000-A 28 AKM3000-A 55 AKM4000-A 111
(mm) 4 6 Note) Weight (g) L M Model D Applicable tubing KQ2C04-00 KQ2C06-00 10.4 12.8 3 3 17 18.5 16 17 8 KQ2C08-00 15.2 20.5 18.5 4 10 KQ2C10-00 18.5 23 21 6 Note) D: Max. diameter 12 KQ2C12-00 20.9 24 22 8 16 KQ2C16-00 26.5 28 25 13 Color Cap: KQ2C Applicable tubing O.D.
regulated) P P A1 A1 B port (P port control type B port regulated) B port (P port control type B port regulated) B1 B1 Pressure gauge connection port Pressure gauge connection port Pressure gauge (G15-10-01) 00 Pressure gauge (G15-10-01) [for odd number stations] 05 Plug (M-5P) M1 Pressure gauge (G15-10-01) [for even number stations] 06 Plug (M-5P) M1 Note) Note that for series ARBY3000
(mm) Model Double Branch "Y" KGUD 4 6 8 10 12 KGH04-00 Applicable tubing O.D. (mm) KGH06-00 Connection threads Model KGH08-00 KGH10-00 KGUD04-01 R 1/8 4 KGH12-00 -02 R 1/4 Bulkhead Union KGE KGUD06-01 R 1/8 6 -02 R 1/4 Applicable tubing O.D.
C[dm3/(sbar)] 0.32 0.25 N.C. 1 0.7 1.2 1.6 0.3 0.6 1 0.3 0.5 b 0.08 0.15 Cv VX311-00 VX312-00 VX322-00 VX332-00 VX313-00 VX323-00 VX333-00 VX324-00 VX334-00 0.29 0.60 0.7 0.4 0.7 1 0.2 0.3 0.6 0.2 0.3 1 0.5 1 1.6 0.3 0.5 0.9 0.25 0.4 1.5 2.2 0.40 0.17 0.64 0.20 0.20 0.82 2.0 3 0.25 0.27 1.1 0.20 0.38 1.6 4 Refer to Glossary on page 31 for details on the max. operating pressure differential
[3][5] 00 16 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 1 0F ABS 10 11 80 12 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 1 8F ABS 90 91 14 13 14 (6) ([4][0]) [4][0] [0][1][F][F] (16)10 8 (7) ([5][0]) [5][0] [0][1][F][F] (16)10 8 (8) ([5][4]) [5][4] [0][1][F][F] (16)10 8 (9) ([5][8]) [5][8] [0][1][F][F] (16)10 8 (10)(DWELL)([6][0]) [6][0] [0][1][F][F] (DWELL) (16)