ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 For 2 stations manifold 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold d Models and Dimensions D Symbol Applicable size d A L D Weight [g] Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4" 18 35 8.5 1 Orange 09 5/16" 20.5 39 10 2 Orange Connector type 1 D sub-connector (25
COIL NO. 3C-101-A24 3C-102-A24 3C-103-A24 3C-104-A24 3C-105-A24 3C-1-K24 3C-2-K24 3C-3-K24 3C-4-K24 3C-5-K24 6 7.8 9 5.2 6.7 7.7 2 2.5 3 12 16 18 24 27 10 14 15 20 23 4 5 6 7.8 9 3C-106-A24 3C-107-A24 3C-108-A24 3C-109-A24 3C-110-A24 3C-6-K24 3C-7-K24 3C-8-K24 3C-9-K24 3C-10-K24 37 48 100 73 82 32 40 85 60 70 12 15 33 24 28 3C-111-A24 3C-112-A24 3C-113-A24 3C-114-A24 3C-115-A24 3C-11-K24
COIL NO. 3C-101-A24 3C-102-A24 3C-103-A24 3C-104-A24 3C-105-A24 3C-1-K24 3C-2-K24 3C-3-K24 3C-4-K24 3C-5-K24 6 7.8 9 5.2 6.7 7.7 2 2.5 3 12 16 18 24 27 10 14 15 20 23 4 5 6 7.8 9 3C-106-A24 3C-107-A24 3C-108-A24 3C-109-A24 3C-110-A24 3C-6-K24 3C-7-K24 3C-8-K24 3C-9-K24 3C-10-K24 37 48 100 73 82 32 40 85 60 70 12 15 33 24 28 3C-111-A24 3C-112-A24 3C-113-A24 3C-114-A24 3C-115-A24 3C-11-K24
Solenoid: No.1 Solenoid, Body Size: 20A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.1 Solenoid, Body Size: 20A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.1 Solenoid, Body Size: 20A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 110VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.1 Solenoid, Body Size: 20A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 24VDC, Lead Wire: Conduit Terminal, Surge Suppressor: -
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 4 (220VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal)
Note) When ordering ejector without valve, select Nil for mounting. 04 KJH C2 Port size 04 06 03 07 !
When the positioning operation is executed in accordance with the point table or program set by setup software (MR Configurator2TM), the diagnosis display changes to "d-06" during single-step feed. For other control mode, the display does not change to "d-06". Refer to section 3.1.9 for details. The status will be displayed with the "MODE" button.
06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 10 to 2F (No used) 10 to 2F (No used) 3A to 30 CC-Link system area 3F to 30 CC-Link system area 3B Remote station READY 3F to 3C CC-Link system area Half numerical data instructions (2 Stations occupied) [Remote register] PLC PLC memory address
06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG (-) 0E ESTOP 0E JOG (+) 0F ALARM 0F FLGTH 10 to 2F (No used) 10 to 2F (No used) 30 to 3A CC-Link system area 30 to 3F CC-Link system area 3B Remote station READY 3C to 3F CC-Link system area 105 - Half numerical data instructions (2 Stations occupied) [Remote register] PLC RWr
Set the value closest to the frequency you need. 00h _ x _ _ Notch depth selection 0: -40 dB 1: -14 dB 2: -8 dB 3: -4 dB 0h x _ _ _ For manufacturer setting 0h Table 5.4 Shaft resonance suppression filter setting frequency selection Setting value Frequency [Hz] Setting value Frequency [Hz] 00 Disabled 10 562 01 Disabled 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06
PB49]4(_ _ _ 1) _ _ x x 5.4 00h _ x _ _ 0:-40dB 1:-14dB 2:-8dB 3:-4dB 0h x _ _ _ 0h 5.4 [Hz] [Hz] 00 10 562 01 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06 1500 16 409 07 1285 17 391 08 1125 18 375 09 1000 19 360 0A 900 1A 346 0B 818 1B 333 0C 750 1C 321 0D 692 1D 310 0E 642 1E 300 0F 600 1F 290 PB18 LPF 3141 100 [rad/s] 18000 [Pr. PB23] [Pr.
PD07 *DI3 3(CN6-3) CN6-3 PD06 000Ah 0 0 CN6-3 CN6-3 PD08 *DI4 4(CN6-4) CN6-4 PD06 000Bh 0 0 CN6-4 CN6-4 6 33 6 PD09 *DO1 1(CN6-14) CN6-14 0002h 0 0 CN6-14 CN6-14 () 00 OFF 02 RD 03 ALM 04 INP 05 MBR 06 DB 07 TLC 08 WNG 09 BWNG 0A SA 0C ZSP 0F CDPS 23 CPO 24 ZP 25 POT 26 PUS 27 MEND 38 1 PT0 39 2 PT1 3A 3 PT2 3B 4 PT3 3C 5 PT4 3D 6 PT5 3E 7 PT6 3F 8 PT7 .
YV Sizes 40-06, 50, and 60 have been added to the AC series. Sizes 40-06, 50, and 60 have been added to the AF, AR(K), and AL. The VHS40-06 and 50 have been added. Size 40-06 has been added to the AFM/AFD. Sizes 40-06 and 60 have been added to the AW(K). Made to order options have been added. Number of pages has been increased from 104 to 112.
A AF20-A AF30-A Air Filter AF40-A P.43 AF40-06-A AF50-A AF60-A AFM AFM20-A P.55 AFM30-A Mist Separator AFM40-A AFM40-06-A AFD AFD20-A Micro Mist Separator P.55 AFD30-A AFD40-A AFD40-06-A AR AR10-A AR20-B AR25-B Regulator AR30-B P.64 AR40-B AR40-06-B AR50-B AR60-B ARlK AR20K-B Regulator with Backflow Function AR25K-B AR30K-B AR40K-B P.67 AR40K-06-B AR50K-B AR60K-B 3 A Modular F.R.L.