Note 5) Dust tight/Low jetproof enclosure (IP65) is not available with interface regulator. 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 1200 1400 1600 Flow rate (l/min(ANR)) ARBQ4000-00-P (P A) How to Order 0.7 Outlet pressure (MPa) 0.6 0.5 Regulating port Solenoid Valve Interface regulator 0.4 A ARBQ4000-00-A-1 0.3 VQ40 (Plug-in type) B ARBQ4000-00-B-1 0.2 P ARBQ4000-00-P-1 0.1 A ARBQ4000-
Note 5) Dust tight/Low jetproof enclosure (IP65) is not available with interface regulator. 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 1200 1400 1600 Flow rate (l/min(ANR)) ARBQ4000-00-P (P A) How to Order 0.7 Outlet pressure (MPa) 0.6 0.5 Regulating port Solenoid Valve Interface regulator 0.4 A ARBQ4000-00-A-1 0.3 VQ40 (Plug-in type) B ARBQ4000-00-B-1 0.2 P ARBQ4000-00-P-1 0.1 A ARBQ4000-
Body type Plug-in type ARBZS2000-00-P-1 Non plug-in type ARBZS2000-00-P-2 Part no. Note) Apply pressure from the P port of the base to operate the interface regulator. To use concurrently with a double check spacer, assemble in the following order: the valve, the interface regulator, and the double check spacer. Body type Plug-in type VVZS2000-26A Non plug-in type Part no.
Body type Plug-in type ARBZS3000-00-P-1 Non plug-in type ARBZS3000-00-P-2 Part no. Note) Apply pressure from the P port of the base to operate the interface regulator. To use concurrently with a double check spacer, assemble in the following order: the valve, the interface regulator, and the double check spacer.
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Surge Suppressor: None, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Surge Suppressor: None, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: S (Surge Suppressor), Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3 (3mm), Style: 5 (COM., Manifold), Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: None, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: -, Orifice: -, Style: -, Option: -, Suffix: -, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Rectifier: -
Model: -, Orifice: -, Style: -, Option: -, Suffix: -, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Rectifier: -
Model: -, Orifice: -, Style: -, Option: -, Suffix: -, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Rectifier: -
Model: 31, Orifice: 3mm, Style: COM., Manifold, Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 24VDC, Electrical Entry: DIN Connector, Surge Suppressor: Light & Surge Suppressor, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3mm, Style: COM., Manifold, Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 24VDC, Electrical Entry: DIN Connector, Surge Suppressor: None, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3mm, Style: COM., Manifold, Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Surge Suppressor: Light & Surge Suppressor, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3mm, Style: COM., Manifold, Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 24VDC, Electrical Entry: Grommet, Surge Suppressor: Surge Suppressor, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3mm, Style: COM., Manifold, Option: For Air -- Seals: NBR, Body: Brass, Coil: Class B, Suffix: Standard, Voltage: 110VAC 50/60HZ, Electrical Entry: Conduit, Surge Suppressor: None, Rectifier: AC Class B Coil w/Full-wave Rectifier
Compatible Fluid: Air, Operating Environment: Dust Resistant, Type: Electromagnetic Type, Switching Type: 3-Port Universal, Application: Multi-Port, Connection Type: -, Plumbing Thread Nominal: -, Operating Temperature Range(°C): -20~60, Driving Type: Linear Motion Type, Operating Pressure Difference Range(MPa): null~0.2, Orifice Diameter(Ø): 3, IP Rating: IP65, Insulation Class: B, Acquired
This is a legacy product. Please contact us for the latest version.sales@ocaire.com