Search Results "VV5QC11-05N7FD2-NS"

Stations: 5 Stations, Port Size: N7 (1/4" One-touch Fitting), Kit Name: F (D-sub Connector 25 Pin), Electrical Entry: D Side, Cable Length: 2 (3.0m Cable 25 Pin), Option 1: D (DIN Rail Mounting), Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: DIN Rail Mounting, Option 2: -

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: None, Option 2: Built-in Silencer, Direct Exhaust

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: Name Plate, Option 2: External Pilot

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: Name Plate, Option 2: -

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: DIN Rail Mount & Name Plate, Option 2: Built-in Silencer, Direct Exhaust

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: DIN Rail Mount w/o DIN Rail, Option 2: -

Stations: 5 Stations, Port Size: 1/4" One-touch Fitting, Kit Name: D-sub Connector 25 Pin, Electrical Entry: D Side, Cable Length: 3.0m Cable 25 Pin, Option 1: DIN Rail Mounting, Option 2: Built-in Silencer, Direct Exhaust

Select R, U, NS, or NZ for the valve when the SI unit output polarity is negative common. * Only Z and NZ are available with a power-saving circuit. Nil None H Built-in !

W-NS: Red LED is ON. No remote are connected. W-NS: Orange LED is ON. Forced output. The base has been set to Forced output mode. Change the mode according to the application. The system has been set to Paring enable. Change the setting to Paring disable when pairing is not conducted. W-NS: Red/green Wireless communication connection is in paring mode. W-NS: LED is OFF.

W-NS: Red LED is ON. No remote are connected. W-NS: Orange LED is ON. Forced output. The base has been set to Forced output mode. Change the mode according to the application. The system has been set to Paring enable. Change the setting to Paring disable when pairing is not conducted. W-NS: Red/green Wireless communication connection is in paring mode. W-NS: LED is OFF.

SI unit SI unit Refer to fault PWR LED and malfunction No.1 MS LED is OFF SI unit Refer to fault PWR(V) LED is OFF No.2 Yes No SI unit Refer to fault MS LED is red No.3 SI unit Refer to fault MS LED is red flashing No.4 SI unit SI unit Refer to fault MS LED is green flashing NS LED is OFF No.5 SI unit Refer to fault NS LED is red No.6 SI unit Refer to fault NS LED is red No.7 flashing SI

(de-energized) 980 m/s2 in X, Y, Z directions 3 times each (de-energized) 500 Vp-p, Pulse width 1 s, Rise time 1 ns Connection Material Weight Power supply / Output connection: 8P connector, Sensor connection: 4P connector (e-con) Housing: PBT, Display: PET, Backside rubber: CR 60 g (Except for any accessories that are shipped together.

Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Between external terminals and housing 1000 VAC, 50/60 Hz for 1 min.

NS LED is OFF The power supply for control and input is OFF, or IP address is not set. The unit received an IP address, but connection is not established. Green NS LED is flashing Green NS LED is ON Connection is established. Connection timeout.

Green MS LED is ON and NS LED is OFF. Communication is normal. Green MS and NS LEDs are both ON. Connection is not established. Green MS LED is ON and Green NS LED is flashing. A component failure inside the SI unit. Red MS LED is ON. Fatal communication error. (Check the following items, and restart.) Check/correct the node address.

SI unit NS LED is No.8 red ON Refer to fault SI unit NS LED is No.9 red flashing Refer to fault SI unit NS LED is No.10 green flashing SI unit NS LED is green ON All valves and Refer to fault valve LEDs are No.11 not operating Valves do not work but valve LEDs are Refer to fault No.12 operating -38No.EX-OMX1001 Troubleshooting table Fault No.1 Fault Probable cause Recommended error handling

PWR) 5(P.23) 6CN1(P.25) 1 LED 5(P.23) 10.1 (P.33) MS ON DataRate OFF DateRate NS PLC PLC PLC PLC I/O PLC NS PLC PLC / 121 2 MSNS / NS PLC PLC / 121 NS Busoff 16. 3 ALM (P.64) 81 - USB USB PC USB USB LEC-W2 COM PC COM COM COM COM PC COM 4 LEC-W2 (LEC W2) (LEC)== =USB =PC (LEC) OFF PC (LEC) (PLC )(PC ) ONOFF PLC 5 10.1 (P.33) 3.(P.12) 82 - 5.