Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: None, Option 2: Built-in Silencer, Direct Exhaust, CE Compliant: -
Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: DIN Rail Mounting, Option 2: -, CE Compliant: -
Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: None, Option 2: None, Option 3: Name Plate, Option 4: None, Option 5: None
Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: None
Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: Built-in Silencer, Direct Exhaust
Stations: 5 Stations, Port Size: C6 (ø6 One-touch Fitting), Common: 0 (+COM), Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust), CE Compliant: Q (CE Compliant)
Stations: 5 Stations, Port Size: ø6 One-touch Fitting, Common: +COM, Option 1: None, Option 2: Built-in Silencer, Direct Exhaust, CE Compliant: CE Compliant
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted plug-in type manifold for VQ2*0* valve, Serial interface (SI) type, Maximum 16 stations available
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Plug-in manifold for VQ2000 series valve, Terminal box connection, Maximum 20 stations available as standard, Optional
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Plug-in manifold for VQ2000 series valve, Terminal box connection, Maximum 20 stations available as standard, Optional
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted plug-in type manifold for VQ2*0* valve, Serial interface (SI) type, Maximum 16 stations available
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD ASSY, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 3.37377 lb, 3.37377 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted plug-in type manifold for VQ2*0* valve, Serial interface (SI) type, Maximum 16 stations available
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, 5-STA, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 3.39511 lb, 3.39511 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted plug-in type manifold for VQ2*0* valve, Serial interface (SI) type, Maximum 16 stations available
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Plug-in manifold for VQ2000 series valve, Terminal box connection, Maximum 20 stations available as standard, IP65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 1.69755 lb, 1.69755 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 3.49064 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Plug-in manifold for VQ2000 series valve, Terminal box connection, Maximum 20 stations available as standard, IP65
R port R port P port P port A, B port A, B port Type of connection Type of connection VV5Q11 VV5Q21 16 Series VQ1000/2000 Kit (D-sub connector) F VV5Q11 VV5Q21 D-sub connector reduces installation labor for electrical connections.