Base Mounted Wiring: 01FD1 (Plug-in w/D-sub Connector, D Side Mtg), Stations: 2 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8)
Base Mounted Wiring: 01FD1 (Plug-in w/D-sub Connector, D Side Mtg), Stations: 4 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8)
Base Mounted Wiring: 01FD1 (Plug-in w/D-sub Connector, D Side Mtg), Stations: 2 Stations, Passage: 3 [P(SUP): Common, E(EXH): Individual, Port A,B(CYL): Side], Port Size: 01 (1/8)
Base Mounted Wiring: 01FD1 (Plug-in w/D-sub Connector, D Side Mtg), Stations: 8 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: N (NPT)
M5 01 Conduit terminal: VF1120-T-M5 01 DIN terminal: VF1120-DVF1120-YVFN Applicable cable O.D. 6 to 8 Applicable cable O.D.
The station No. of CC-Link is shown. (01 to 64) Set the CC-Link communication speed. STATION NO. Switch name Set range Description STATION NO. (X10) Set upper bits of the station. 01 to 64 STATION NO. (X1) Set lower bits of the station. The CC-Link address setting at the time of the factory shipment is set in 01".
(When operation is commanded through PLC, this alarm will be generated depending on the input signal interval and the holding time of signals) The step data is not registered. (01-051) Operation data error B RESET
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Set step data is not registered on list. (01-051) < Countermeasure > (1) Make sure that the Movement MOD in the step data is not "Blank Step data ALM2 B RESET (Disabled)" and that numbers [1(ABS)] and [2(INC)] or input in the numerical instruction operation
(When operation is commanded through PLC, this alarm will be generated depending on the input signal interval and the holding time of signals) The step data is not registered. (01-051) Operation data error B RESET
Alarm_Co mment_1 11 (01-111) 6F C RESET Input
Alarm_Co mment_1 11 (01-111) 6F C RESET Input
PLC <> 1 1ABS 2INC 2PLC 15ms 30ms 14.2[2] (P.54) No. (01-051) No.
(PLC ) No. (01-051) <> (1)( )1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2 [2](P.53) No. B RESET <>(+) (-) (JOG ) <>(+) (-) (01-052) B RESET -63- () 12 (12 0 ) (2) (3) (4) (5) (6) (7) Alarm _Comment _058 (01-058) 3A B RESET <>No.
The station No. of CC-Link is shown. (01 to 64) The communication speed of CC-Link is shown. STATION NO Switch name Set range Description STATION NO.(X10) Set upper bits of the station. 01 to 64 STATION NO.(X1) Set lower bits of the station. The CC-Link address setting at the time of the factory shipment is set in 01".
PLC No. 1-051 <> PLC 15ms 30ms 2(P.60) No.
How to Order Valve VFA 3 1 3 0 01 VFA 3 1 3 0 01 Pilot port direction Series 1 3 5 Nil: Upward P: Lateral VFA1000 VFA3000 VFA5000 Pilot port Type of actuation 1 2 3 4 5 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center Pilot port Only 1 and 2 are available with the VFA1000.
1 8 1 4 1 8 1 4 1 8 1 4 VFA32302 position double 0.17 1 8 14.4 (0.8) 18 (1) 01 02 (EXH: ) 1 8 VFA3330-X1 3 position closed center 0.32 1 8 11.7 (0.65) 14.4 (0.8) 01 02 Base mounted (EXH: ) 1 8 VFA3430-X1 3 position exhaust center 0.32 1 8 14.4 (0.8) 18 (1) 01 02 (EXH: ) 1 8 VFA3530-X1 3 position pressure center 0.32 1 8 14.4 (0.8) 9.9 (0.55) 16.2 (0.9) 10.8 (0.6) 01 02 (EXH: ) 1 8 1 4 3
VZA VTA VPA342 VPA542 VGA VPA VPA 21.5 28 VPA3 15 22 1563 3 Port/Air Operated Valve Base Mounted/Single Unit VPA300/500/700 Series How to Order VPA 3 4 4 1 01 A Series 3 5 7 VPA300 series Type of actuation A B N.C. (Normally closed) N.O.