Closed cenler NVFR2300 NVFR2310 VB 0.7 1 8 0 30 or less 0.95 (0,43) V4 Exhausl center NVFR2400 NVFR24 t0 lb 0.7 180 30 or less 0.95 {0.43) th Pressure center NVFR2500 NVFF25t0 !
Applicable model KQ01-P01NJ KQ2E01-00NJ, KQ2E03-00NJ KQ07-P01NJ KQ2E07-00NJ KQ01-P01AJ KQ2E01-00AJ, KQ2E03-00AJ KQ07-P01AJ KQ2E07-00AJ KQ01-P01N KQ2E01-00N, KQ2E03-00N, KQ2E01-35N KQ2E03-35N, KQ2LF01-00N, KQ2LE03-00N KQ01-P01A KQ2E01-00A, KQ2E03-00A, KQ2E01-35A KQ2E03-35A, KQ2LF01-00A, KQ2LE03-00A KQ05-P01N KQ2E05-00N, KQ2E07-00N, KQ2E05-34N KQ2E07-35N, KQ2LF05-00N, KQ2LE07-00N KQ09-P01N
How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polarity display Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Connector Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000
Note 2) Min. operating frequency is once in 30 days.
Note 2) Min. operating frequency is once in 30 days.
How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polar indication Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Connector Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000
How to Order Connector Assembly 30 4A SY100 For DC: 30 1A SY100 For 100 VAC: 30 2A SY100 For 200 VAC: 30 3A SY100 For other voltages of AC: Caution When making connections, please note that using other than the specified size (3.5 to 7) cabtire cable will not satisfy IP65 (enclosure) standards.
Applicable manifold model DXT154-34-1A VV5F1-31 AN120-M5 VV5F1-31 AN110-01 VV5F1-30 DXT144-13-2A VV5F1-30/31 Description Throttle valve VV5F1-30 VFS Silencer VS4 Blanking plate assembly VQ7 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) VV5F1-30-051 1 pc.
For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polarity display Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Nil 6 10 15 20 25 30 50 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm (For DC) 10-SYJ3123-5LO-M3 SY100-30-4A-20 Connector How to
V100 SY How to Order Connector Assembly SYJ For DC: SY100 30 4A VK For 100 VAC: SY100 30 1A Groove Cover VZ For 200 VAC: SY100 30 2A Pin Cover VT Groove For other voltages of AC: SY100 30 3A DC Polarity display Lever Pin VP Lead wire length Without lead wire: SY100 30 A -+ Socket (with connector and 2 of sockets only) Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000
Lead wire color 30 4A SY100 For DC: Red, Black 3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals according to the connection method, and fasten them securely with the terminal screws. 30 1A SY100 For 100 VAC: Blue 30 2A SY100 For 200 VAC: Red 30 3A SY100 4. Secure the cord by fastening the ground nut.
M8 connector 1-5-53 54 Series SYJ7000 How to Order Connector Assembly for L/M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil
circuit (24, 12 VDC only) SY100-30-2AFor 200 VAC: T VQZ For other voltages of AC: SY100-30-3APower saving circuit is not available in the case of W type.
Tightening torque 0.3 to 0.4Nm Washer Connector assembly part numbers Grommet (rubber) Housing SY100 30 4A For DC: (Light mounting location) (Rating symbols) See table below Lead wire length Without lead wires: SY100 30 A (Connector, socket x 2pcs. only) Terminal block 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm For DC SY3160-5LO-M5 SY100-30-4A-20 Nil 6 10 15 20 25 30 50 Terminal
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).
Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)
60 Hz DC Coil rated voltage (V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Allowable voltage fluctuation (%) Note) Power consumption (W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30
SY7000221-1A [for 10 valves (30 pcs.)] SY7000222-1A [for 10 valves (30 pcs.)]