M8 connector 1-5-53 54 Series SYJ7000 How to Order Connector Assembly for L/M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil
circuit (24, 12 VDC only) SY100-30-2AFor 200 VAC: T VQZ For other voltages of AC: SY100-30-3APower saving circuit is not available in the case of W type.
Manifold Type: 30 (Top Ported Common EXH), Stations: 8 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 2 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 3 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 6 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 5 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 12 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: 30 (Top Ported Common EXH), Stations: 7 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)
Manifold Type: Top Ported Common EXH, Stations: 8 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 2 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 3 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 6 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 5 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 12 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
Manifold Type: Top Ported Common EXH, Stations: 7 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Tightening torque 0.3 to 0.4Nm Washer Connector assembly part numbers Grommet (rubber) Housing SY100 30 4A For DC: (Light mounting location) (Rating symbols) See table below Lead wire length Without lead wires: SY100 30 A (Connector, socket x 2pcs. only) Terminal block 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm For DC SY3160-5LO-M5 SY100-30-4A-20 Nil 6 10 15 20 25 30 50 Terminal
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.