SMC Corporation of America
Elite Part Number Search
Search Results "VV307-01-062-01F-F"

Female thread type Female thread type Model Port size Model Port size KK130P-01F -02F -03F -04F -N01F -N02F -N03F -N04F KK130S-01F -02F -03F -04F -N01F -N02F -N03F -N04F Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8 Rc1/2 Rc1/2 NPT1/8 NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT3/8 NPT1/2 NPT1/2 Refer to the how to order on page 1 for the sleeve lock mechanism provided type.

VM830-01-00 VM830-01-01 VM-01F VM830-01-13 VM830-01-14 VM-13F VM-14F Actuator replacement is available. How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 Rc 01 1 8 Roller lever 01 1 8 NPT N01 Adjustable roller lever 13 G F01 1 8 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.

VM830-01-00 Actuator Basic Roller lever Adjustable roller lever Adjustable rod lever VM830-01-01 VM-01F VM830-01-13 VM830-01-14 VM-13F VM-14F Actuator replacement is available.

(T) (F) (T) VV802-P-01 (Size 18 mm) 18 9 1/8" VV801-P-03 (Size 26 mm) By mounting individual SUP spacers on a manifold block, it is possible to provide individual SUP ports for each valve. 22.5 11 Size 18 mm 1(P) 4(A) 129.5 61 2(B) 1(P') 19 26 13 3/8" 3(R2) 5(R1) Circuit diagram 28.6 14.3 Size 26 mm 112 Individual EXH spacer 49 12.5 (F) (T) (F) (T) VV802-R-01 (Size 18 mm) 18 9 1/8" VV801

(Refer to Manifold on page 17.) 12 12 stations Common Release Pressure (PD) Port Size Note) Common Supply (PV) Port Size 01 01N 01F M5 Without PD port (PV = PD) M5 x 0.8 (PV PD) Rc1/8 NPT1/8 G1/8 M5 x 0.8 Nil M5 Note) Refer to on page 1 for the combinations of supply valve and release valve selectable.

400 NCQ8B150-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B200-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B250-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B300-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B400-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 #10-24UNC-1 1/8 1 1/4

VM830-01-00 VM830-01-01 VM-01F VM830-01-13 VM830-01-14 VM-13F VM-14F Actuator replacement is available. How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 Rc 01 1 8 Roller lever 01 1 8 NPT N01 Adjustable roller lever 13 G F01 1 8 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.

Material Applicable blow gun model Model Male thread nozzle 1 to 2.5 Male thread nozzle 3 to 4 Width across flats 17 Nozzle type P5670129-01 P5670129-01F P5670129-02 P5670129-02F HNBR Fluororubber HNBR Fluororubber VMG1mm-m-01 to 04 VMG1mm-m-05 to 07 m25 VMG1m-mm-1 to 04 Width across flats 17 m23.5 VMG1m-mm-05 to 07 Cover for copper extension nozzle (mm) Nozzle cover part no.

1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N NPT1/8 2 01F G1/8 M5 M50.8 M50.8 M-5P ZB03 ZB04 ZB05 ZB06 PV N.C.

Port size IDK Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Availability Plug Yes No No Yes Socket Yes Yes No No Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.

. (3) Common supply pressure (PV) connecting port size (4) Common vacuum burst pressure (PD) port Note 2) 01 Rc1/8 01N NPT1/8 01F G1/8 M5 M50.8 NIL Without PD port (PV = PD) M5 M50.8 PVPD Note 2)Refer to model indication for single unit (4) for the combinations of supply valve and release valve selectable. 14 - Doc. no.

Displacement of Section A when force acts on Section F Displacement of Section A when force acts on Section F Guide central axis (1 axis type) F A F F For the double axis type, this is the cylinder's central axis.

3 3 Ports N O O F P O R T S T H R E A D A C T U AT O R PT N NPT * Remove (N) when ordering 00 Basic Type 01 Roller Lever 13 Adjustable Roller Lever 14 Adjustable Rod Lever H O W T O O R D E R NVM800 A C T U AT O R O N LY Roller lever VM-01F Adjustable roller lever VM-13F Adjustable rod lever VM14F FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE E104 & N261


For valves which had an “E” prefix, the thread type now needs to be indicated in the part number (e.g., symbol “F” for G thread).
Valve part number example: EVT307-5DO-01-Q→VT307-5DO-01F-Q
Example of valve series with an “N” prefix: NVT3, NVO3, NVK, NVP, NVF, NVS, NVN, NVY, etc.

to 0 Alarm 1 7 F to 0 Pushing force F to 8 Alarm 2 8 7 to 0 Alarm 3 8 F to 0 Trigger LV F to 8 Alarm 4 9 F to 0 Sub Function 9 F to 0 Pushing Occupation speed 10 F to 0 Address 10 F to 0 Moving force area 11 F to 0 Address 11 F to 0 Area 1 12 F to 0 DATA(H) 12 F to 0 Occupation (always 0) area 13 F to 0 DATA(L) 13 F to 0 Area 2 14 F to 0 Occupation 14 F to 0 area 15 F to 0 15 F to 0 In position

Alarm _Comment _062 (01-062) 3E B RESET Caution If the operation method of step data is relative coordinated movement, note the location where the operation starts and the distance traveled. If the location is out of the stroke range when the power is supplied, this alarm is generated. Move the table within stroke range, and supply power. Reacting force is outside limit when pushing.

Alarm_Co mment_1 11 (01-111) 6F C RESET Input The motor speed exceeds a specific level due to an external force, etc. Speed exceeded set value (01-144) Make improvements so that the motor speed will not exceed the maximum speed of the actuator.

Alarm_Co mment_1 11 (01-111) 6F C RESET Input The motor speed exceeds a specific level due to an external force, etc. Speed exceeded set value (01-144) Make improvements so that the motor speed will not exceed the maximum speed of the actuator.

Stations: 6 Stations, Exhaust Style: 2 (Common Exhaust), A Port Size: 01 (1/8 Common Exhaust/Individual Exhaust), Thread: Rc