SMC Corporation of America
Elite Part Number Search
Search Results "VNB611B-40A-3D"

Size: 6 (ø40), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 40A (1 1/2), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Terminal)

Size: 6 [ø40(ø28)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 40A (1 1/2), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Terminal)

Size: ø40, Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1 1/2, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -

Size: 6 [ø40(ø28)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1 1/2, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliance: -

Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1 1/2, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 40, Voltage: 110 V AC

[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]

32 3C 0D 06 32 OD Set at 25.0 deg.C 31 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Answer -1.52 deg.C Reading offset 01 32 05 36 36 3D

31 32 35 30 30 03 32 3C 0D 06 32 OD Set at 25.0 deg.C 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Reading offset 2 01 32 05 36 36 3D

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061) (1) Make sure that the Movement MOD in the step data is not 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061) (1) Make sure that the Movement MOD in the step data is not 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) (1) Make sure that the Movement MOD in the step data is not Alarm _Comment _061 (01-061) 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

(When operation is commanded through PLC, this alarm will be generated depending on the input signal interval and the holding time of signals) (1) Make sure that the Movement MOD in the step data is not Alarm _Comment _061 3D B RESET (01-061) "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time

B RESET >+JOG (01-052) >+B RESET 65 - 112 12 0 2 3 4 5 6 7 Alarm _Comment _058 (01-058) 3A B RESET No.base PLC <> 1 1ABS 2INC 2PLC 2 14.2[2] (P.54) Alarm _Comment _061 (01-061) 3D B RESET <>+ <>+Alarm _Comment _062 (01-062) 3E B RESET <> (01-096) C RESET <> (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF

(PLC ) Alarm _Comment _061 (01-061) <> (1) ()1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2[2](P.53) 3D B RESET (+)(-) Alarm _Comment _062 (01-062) (+)(-) 3E B RESET <> (01-096) C RESET <> -64- (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON (SVRE ON) DRIVE ON (01-099) <> SET OFF DRV C RESET <> <>12 (01-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] <> <>

In this case, loosen the screw with washer (3f) and place a lead wire (3d) into the bracket, and then re-tighten the screw. Caution DlN Terminal (Connection) The solenoid is wired with male terminals of DIN connector as shown below. Connect with corresponding terminals of the connector. Can be used as either + COM or COM.

In that case, loosen the self-up screw 3f, insert the lead wire into the bracket 3d and screw in the screw again. b) The maximum size of the crimped terminal 9 is 1.25mm2 to 3.5 for O terminal and 1.25mm2 to 4 for Y terminal. c) Use a cable with outside diameter of 6 to 12mm for the cable 8.

In that case, loosen the screw (3f) and place a lead wire into the bracket (3d), and then tighten it once again. b) The maximum size for the round terminal (9) is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c) Cable (8) outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal (7) before using. 3.

In that case, loosen the screw (3f) and place a lead wire into the bracket (3d), and then tighten it once again. b) The maximum size for the round terminal (9) is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c) Cable (8) outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal (7) before using. 3.

In that case, loosen the screw (3f) and place a lead wire into the bracket (3d), and then tighten it once again. b) The maximum size for the round terminal (9) is 1.25 mm2 3.5 and for the Y terminal is 1.25 mm2 4. c) Cable (8) outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal (7) before using. 3.

[%F.S.] 4 3 2 1 OUT side IN side 0 0 D 2D 3D 4D 5D 0 1 2 3 4 5 Straight pipe length The smaller the piping size, the more the product is affected by the length of straight piping. The straight piping length shall be a minimum of 5 times (5D) the piping size to achieve a stable measurement.