SMC Corporation of America
Elite Part Number Search
Search Results "VNB514BS-32A-5DZ-Q"

-20(-Q) 10-SS5YJ5-20P(-Q) Applicable manifold base 10-SS5YJ5-40(-Q) 10-SS5YJ5-41(-Q) 10-SS5YJ5-42(-Q) 10-SS5YJ5-43(-Q) 10-SS5YJ5-41P(-Q) 10-SS5YJ5-43P(-Q) Applicable manifold base Type 10-SS5YJ5-41(-Q) Type 10-SS5YJ5-42(-Q) Type 10-SS5YJ5-43(-Q) Type 10-SS5YJ5-41P(-Q) Type 10-SS5YJ5-43P(-Q) Caution Mounting screw tightening torque M2.5: 0.45 Nm Use caution to the assembly orientation

Note 3) Vacuum pilot type CE-compliant pilot solenoid valves will become VO307VD DZ-Q. 2 1 1 2 569 A VNB Series How to Order Pilot Solenoid Valves Valve size 1/2/3/4 Valve size 5/6/7 and vacuum pilot type VO307 Q 1 5 D SF4 5 D 23 Q Body option CE-compliant CE-compliant Coil rated voltage CE-compliant Nil Q Standard Vacuum pilot Nil V CE-compliant Nil Q 1 2 3 Note 1) 100 VAC 50/60 Hz 200

External pilot solenoid Air operated Pilot Solenoid Valve Specifications Port size 6A to 25A 32A to 50A VO307-1 VO307D DZ-Q Pilot solenoid valve SF4--23 SF4D DZ-23-Q Symbol Grommet, Grommet terminal Conduit terminal DIN terminal Grommet, DIN terminal VNA VNA Valve type Type N.C. N.O. C.O.

SY 3 5 1 0 0 1 q w r e t y u i o !0 !1 Base mounted q Series !

SY3000-54-2C(-Q) SY3000-54-1C(-Q) SY5000-54-1C(-Q) SY7000-54-1C(-Q) Assembly part no.

0 t t r i w e r i u w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!

VVZ400-32A-11 pc. (Blanking plate) VV3Z4-50-061-01 (6 stations) VZ415-1G3 pcs. VZ425-1G2 pcs. VVZ400-32A-21 pc.

Component Parts Replacement Parts No. u i Description Description Sub-plate Pilot valve No. q w e r t y Note Aluminum die-casted Part no.

Size: 5 [ø32(ø22)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: FPM Seal, Body Material: Stainless Steel Body, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1 1/4, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -

VNB1 -6A, 8A, 10A VNB2 -10A, 15A VNB3 -20A VNB5 -32A, 32F VNB6 -40A, 40F VNB7 -50A, 50F VNB4 -25A VNB54 -32A, 32F VNB64 -40A, -40F VNB74 -50A, 50F No.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P : Pressure drop (P1 P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures Multiply

Bracket (Option) VEX7-32A Hexagon socket head cap screw M6 =10 (4 pcs.)

G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEXA-18-2A VEX1-18-1A VEX3-32A VEX5-32A VEX7-32A VEX9-32A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G36-10-01 G46-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures

Disassembly 1) After loosening the screw q, then if the housing w is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull the screw q out of the housing w. 3) On the bottom part of the terminal block e, theres a cut-off part o.

0 t t r i w e r i u w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!

0 t t r i u w y e q r i w e q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!0 t r i w y e q o Replacement Parts (For valve) Description VQ7-8-FG-SVQ7-8-FG-DVQ7-8-FPG-DVQ7-8-FG-S-R VQ7-8-FG-D-R VQ7-8--D-R VQ7-8--DNumber q w e r t y u i o !

Description VEX11001 02 External pilot solenoid VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 B F G VEX3-32A VEX5-32A VEX7-32A VEX9-32A VEX1-18-1A G27-10-01 G36-10-01 Bracket (With bolt and washer) JIS Symbol G46-10-01 VEX1-18-2A Pressure gauge Note) Air operated External pilot solenoid Note) When requiring a gauge different than that mentioned above, specify the

Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.

VNA1A -6A, 8A, 10A VNA2 -10A, 15A VNA3 -20A VNA4 -25A VNA5 -32A VNA6 -40A VNA7 -50A No.