SMC Corporation of America
Elite Part Number Search
Search Results "VHS20-F02A"

Unit: N m Applicable models VHS20-D VHS30-D VHS40-D VHS40-06-D VHS50-D Max. moment (M) 14.5 16 19.5 35 45 Max. moment (M) = Length (L) x Load (F) Length (L) Load (F) 6. For piping into the exhaust port, recommended installing a silencer.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.

ACG20B ACG30B ACG40B Model Description Pressure gauge Note 1) GB2-10AS GB3-10AS GB4-10AS GB2-10AS GB2-3AS AD27 Y200 Y200T IS10M-20 VHS20-01, 02 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

ACG20B ACG30B ACG40B Model Description Pressure gauge Note 1) GB2-10AS GB2-3AS AD27 Y200 Y200T IS10M-20 VHS20-01, 02 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

Specifications Model Standard specifications P1 P2 A B C D E F G H I VHS20 1/8, 1/4 1/8 66.4 22.3 40 37.5 14 46.6 33.6 28 37.5 VHS30 1/4, 3/8 1/4 80.3 29.4 53 49 19 52 38 30 49 VHS40 1/4, 3/8, 1/2 3/8 104.9 38.5 70 63 22 58 44 36 63 VHS40-06 3/4 1/2 110.4 42 75 63 22 58 44 44 63 Model Port size Specifications IN, OUT EXH IN OUT OUT EXH C(dm3/sbar) b Cv C(dm3/sbar) b Cv VHS20 1/8 1/8 2.4

ACG20B ACG30B ACG40B Model Description Pressure gauge Note 1) GB2-10AS GB3-10AS GB4-10AS GB2-10AS GB2-3AS AD27 Y200 Y200T IS10M-20 VHS20-01, 02 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.

22.8 0.49 6.3 P2 (Port size) EXH Model P1 P2 A B C D Applicable size VHS20-D 1/8, 1/4 1/8 48.5 23 40 37 AC20-D VHS30-D 1/4, 3/8 1/4 55 32 53 49 AC30-D VHS40-D 1/4, 3/8, 1/2 3/8 69.7 41.3 70 63 AC40-D VHS40-06-D 3/4 1/2 71.7 43.3 75 63 AC40-06-D VHS50-D 3/4, 1 1/2 86.5 44.5 90 80 AC50-D/AC60-D Model E F G H Applicable size VHS20-D 28 42 17.5 40 AC20-D VHS30-D 38 53 20 53 AC30-D VHS40-D 52

a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

/sbar) 2.5 3.1 6.2 7.0 8.5 11.6 13.3 17.7 Cv 0.65 0.88 1.7 2.3 2.0 3.0 3.8 5.0 Cv 0.69 0.84 1.7 1.9 2.3 3.1 3.6 4.8 b 0.43 0.40 0.45 0.41 0.49 0.45 0.39 0.31 b 0.39 0.51 0.38 0.41 0.35 0.40 0.43 0.37 1/8 1/4 1/4 3/8 1/4 3/8 1/2 3/4 1/8 VHS20 1/4 VHS30 3/8 VHS40 1/2 VHS40-06 Note) Use an air filter on the IN side for operating protection.

EXH Flow Rate Characteristics Model Port size Flow rate characteristics Model Standard specifications P1 P2 A B C D E F G H I VHS20 1/8, 1/4 1/8 66.4 22.3 40 37.5 14 46.6 33.6 28 43 VHS30 1/4, 3/8 1/4 80.3 29.4 53 49 19 52 38 30 49 VHS40 1/4, 3/8, 1/2 3/8 104.9 38.5 70 63 22 58 44 36 63 VHS40-06 3/4 1/2 110.4 42 75 63 22 58 44 44 63 VHS50 3/4, 1 1/2 134.3 53 90 76 26 76 61 53 81 IN, OUT EXH

AC50 AC40 AC25 AC30 AC20 SMC Corporation of America 10100 SMC Blvd., Noblesville, IN 46060 www.smcusa.com VHS20 VHS30 VHS40 VHS50 SMC Pneumatics (Canada) Ltd. www.smcpneumatics.ca (800) SMC.SMC1 (762-7621) e-mail: sales@smcusa.com An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.