0.50 0.51 0.50 0.38 0.46 2.3 2.0 2.1 2.3 2.1 2.1 2.5 2.2 2.2 2.2 0.26 0.25 0.25 0.26 0.24 0.20 0.23 0.30 0.23 0.26 0.55 0.49 0.51 0.54 0.50 0.50 0.59 0.55 0.52 0.53 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 C6 C8 1/8 C6 C8 1/8 1/8 C6 C8 Type 10-SS5YJ7-20 Body ported Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 10-SYJ723
8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 C6 C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted SYJ74 for internal pilot Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold
0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 0.59 0.62 0.54 0.66 0.56 0.54 0.59 1/8 1/4 1/8 1/4 Body ported for internal pilot 10-SYJ72M 1/8 1/8 1/8 1/8 C6 C8 Base mounted for internal pilot 10-SYJ74M 1/4 1/4 10-SS3YJ7-42-C6 1/4 10-SS3YJ7-42-C8 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example)
(A port) P=19 21 22.5 9.5 R X R X P P 43 43 71.5 [72.8] 67.5 81.1 35 35 C6: MAX. 6 C8: MAX. 6.5 C6: MAX. 6 C8: MAX. 6.5 (Lead wire length) 300 80.6 [87.1] 300 (Lead wire length) (P/R port) 4-Rc (PT)1/4 57.1 [ ] for AC Other dimensions are the same as the grommet
0.30 0.32 0.24 0.57 0.37 0.45 0.55 0.36 0.50 0.51 0.50 0.38 0.46 2.3 2.0 2.1 2.3 2.1 2.1 2.5 2.2 2.2 2.2 0.26 0.25 0.25 0.26 0.24 0.20 0.23 0.30 0.23 0.26 0.55 0.49 0.51 0.54 0.50 0.50 0.59 0.55 0.52 0.53 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 C6 C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted
Type SS3YJ7-40 1/8 1/8 1/8 1/8 C6 C8 Type SS3YJ7-41 Base mounted for internal pilot Type SS3YJ7-42-01 SYJ74 1/4 1/4 Type SS3YJ7-42-C6 Type SS3YJ7-42-C8 1/4 Body ported for external pilot SYJ72R 1/4 1/8 2.2 0.34 0.55 2.4 0.32 0.62 Type SS3YJ7-21R Type SS3YJ7-41R 2.2 2.0 1.6 2.1 0.35 0.27 0.32 0.24 0.59 0.47 0.39 0.51 2.4 2.2 2.2 2.3 0.36 0.32 0.27 0.31 0.66 0.56 0.54 0.59 1/8 1/8 C6 1/4 1
0.35 0.27 0.32 0.24 0.55 0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 0.59 0.62 0.54 0.66 0.56 0.54 0.59 1/8 1/4 1/8 1/4 Body ported for internal pilot SYJ72 Type SS3YJ7-21 Type SS3YJ7-40 1/8 1/8 1/8 1/8 C6 C8 Type SS3YJ7-41 Base mounted for internal pilot Type SS3YJ7-42-01 SYJ74 1/4 1/4 Type SS3YJ7-42-C6 Type SS3YJ7-42-C8 1/4 Body ported for
1.6 2.1 0.34 0.39 0.35 0.35 0.27 0.32 0.24 0.55 0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 Body ported for internal pilot 0.59 0.62 0.54 0.66 0.56 0.54 0.59 1/8 1/4 1/8 1/4 10-SYJ72M 1/8 1/8 1/8 1/8 C6 C8 Type 10-SS3YJ7-40 Type 10-SS3YJ7-41 Base mounted for internal pilot 10-SYJ74M 1/4 1/4 Type 10-SS3YJ7-42-01 Type 10-SS3YJ7-42-C6 1/4 Type
C8 (A, B port) D side Bottom ported: VV5FR2-01TStation 2Port size C6, C8 Light/Surge voltage suppressor (At FZ) 2-Rc 1/8 (PE port) 2-G 3/4 (Electrical entry) C6: Max. 6 C8: Max. 6.5 6-Rc 1/4 (P, EA, EB port) With terminal block (One-piece junction cover): VV5FR2-01T1Station 1Port size U side 5n-Rc 1/8 (Pitch) P = 28 Stations 2n-Rc 1/8, 1/4 C6, C8 (A, B port) D side Bottom ported: VV5FR2-
Flow Characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Flow characteristics Port size Model 4, 2 (A, B) Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b 1, 5, 3 (P, EA, EB) SS5X3-45l SS5X5-45l C6 C8 0.88 2.2 0.21 0.24 0.22 0.53 0.95 2.5 0.18 0.18 0.22 0.58 C8 C10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.
Function 2-Hexagon socket head set screw H4 4/2.5 CJ-5H-4 With a fixed orifice (0.8) H6 6/4 CJ-5H-6 MH4 4/2.5 M-5H-4 Without fixed orifice MH6 6/4 M-5H-6 Dimensions (Dimensions other than below are the same as standard type.)
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area
H4 4/2.5 CJ-5H-4 With a fixed orifice (0.8) H6 6/4 CJ-5H-6 MH4 4/2.5 M-5H-4 Without fixed orifice MH6 6/4 M-5H-6 Dimensions (Dimensions other than below are the same as standard type.) Hose nipple Width across flats 8(7) (12) The above figure shows the 6/4 hose nipple mounting dimensions.
Embedded type One-touch fitting Applicable tubing O.D.: 8 C8 3-7-35 36 Series VZS3000 Plug-in type, Non plug-in type Manifold with Control Unit Example for manifold Plug-in type VV5ZS3-51FStation 1Port size Classification of control unit Individual EXH spacer Manual override Indicator light 4-4.5 mounting hole Double check spacer 2n-Rc 1/8, 1/4, C6, C8 U side (n) Individual SUP spacer (1)
Model: 4 (VDW40), Voltage: 5 (24VDC), Power-saving Circuit: None, Electrical Entry Direction: Piping Direction, Orifice Diameter: 6 (6.0 mm), Port Connection Type: C8 (One-touch fitting for ø8), Body Material and Coil Insulation Type: PPS Body, NBR Seal, Class B Coil, Option: None
Compatible Fluid: Air / Water, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Resin, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ8, Operating Temperature Range(°C): -10~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 6, IP Rating: IP65, Acquired
Series P port/Thread
VF Flow Characteristics VFR Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size Manifold VP4 1(P), 5/3(R) port 2(B), 4(A) port C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VV5Z3-45 VZ34 C8 C8 0.59 0.76 0.28 0.23 0.15 0.18 0.83 0.86 0.34 0.29 0.22 0.22 C4 C6 VZS Note) Value at manifold base mounted, 2 position single operating VFS How to Order Manifold VS4 Instruct by specifying