CN1 CN2 Shuts off 3 12 13 9 10 7 8 20 17 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG P5 19 OP 4 11 LG V+ 1 P5 LG MR MRR MD MDR SD 20 12 7 6 SG P5 LG MR MRR MD MDR SHD P5 LG MR MRR MD MDR SHD 7 8 1 2 4 5 9 7 8 1 2 4 9 Detector 17 16 Plate 5 (Note 2) 11 15 14 2 12 (Note 6) Connect the shielding wire securely to the ground plate inside the connector.
Terminal resistance Terminal resistance Circuit diagram SD+ SD SG 2 SD+ 7 SD 5 SG 2 SD+ 7 SD 5 SG 2 SD+ 7 SD 5 SG Master This product This product This product (1st slave) (2nd slave) (31st slave) Do not connect with other pins.
Symbol Symbol Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 220 1/2W + + + + 1 1 1 2 2 2 SG SG SG SG 5 5 5 Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
Signal contents RS-232C RS-485 1 Unused BUS+ 2 RD Unused 3 SD Unused 4 Unused Unused 5 SG SG 6-8 Unused Unused 9 Unused BUS 8 Contact b for output cutoff alarm (closed when alarm occurs) 3 9 Contact a for upper/lower temp. limit alarm (open when alarm occurs) 10 Common for upper/lower temp. limit alarm 4 11 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 12-14 Unused
Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + 1 1 1 + 2 2 2 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + + 1 1 1 2 2 2 9 9 9 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
humidity range (%) RS485 (Modbus protocol compliant) EEPROM LED (Green/Red) one of each Forced-lock release terminal Note 3) I/O cable: 5 or less Actuator cable: 20 or less Natural air cooling 0 to 40 (No condensation and freezing) 35 to 85 (No condensation and freezing) 10 to 60 (No condensation and freezing) 35 to 85 (No condensation and freezing) Between the housing (radiation fin) and SG
system Operating temperature range Operating humidity range [%RH] Storage temperature range Storage humidity range [%RH] Insulation resistance [M] Weight I/O cable: 5 or less Actuator cable: 20 or less Natural air cooling 32 to 104F (0 to 40C) (No freezing) 90 or less (No condensation) 14 to 140F (10 to 60C) (No freezing) 90 or less (No condensation) Between the housing (radiation fin) and SG
1 24V 0V S1 S2 SG R1 R2 FG SDA SDB SG RDA RDB FG 24V 0V Description Lighting during data reception Description Lighting when power is turned ON LED TRD LED POWER RUN RD SD ERR. Lighting when data transmission with the master station is normal Blinking when received data is normal; RUN/ERR Stations are counted from station 1 on the D side.
release terminal Note 3) Parallel input Parallel output Pulse signal input Compatible encoder Serial communication Memory LED indicator Lock control I/O cable: 1.5 or less (Open collector), 5 or less (Differential) Actuator cable: 20 or less Natural air cooling 0 to 40 (No freezing) 90 or less (No condensation) 10 to 60 (No freezing) 90 or less (No condensation) Between the housing and SG
SET MODE Operation keys SD SG RD RS-232C COM S.STOP OUT1 OUT2 OUT3 OUT4 OUT5 100 to 240 VAC Power supply Output terminal Communication terminals Display detail Upper limit Functions (PRESCL, OFFSET, STOP, OUTPUT, INPUT, BACKUP, RS-232, UNIT) Mode indicators COUNT PRESET FUNC. BANK NO.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V Separate arrangements should be made for the BCD cable with connector.
SET MODE RZQ SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MI W S Includes all functions of the CEU1.
Name of terminal block (LED) Note VF POWER RUN SD RD ERR RUN ERR TRD 10 1 24V 0V + + FG VFR L1 L2 SG L1 L2 SG 24V 0V VP7 Details It lights when transmission is normal and PLC is in the cperation mode. LED name LED name POWER RUN Details It lights when power is turned ON. RUN It lights when power is turned ON and slave stations are in normal operation.
to 85 (No condensation and freezing) 14 to 140 (No condensation and freezing) 35 to 85 (No condensation and freezing) Serial communication Memory LED indicator Lock control Cable length (m) Cooling system Operating temperature range (F) Operating humidity range (%) Storage temperature range (F) Storage humidity range (%) Insulation resistance (M) Between the housing (radiation fin) and SG
1 SD+ 9 SD 5 SG 1 SD+ 9 SD 5 SG Circuit diagram Terminal resistance 120 Master This product This product (1st slave) (31st slave) Be sure to wire to the correct pin numbers according to the diagram.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MVGQ CC Please consult with SMC separately for a BCD cable with connector.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MVGQ CC Please consult with SMC separately for a BCD cable with connector.