Signal contents RS-232C RS-485 1 Unused BUS+ 2 RD Unused 3 SD Unused 4 Unused Unused 5 SG SG 6-8 Unused Unused 9 Unused BUS 8 Contact b for output cutoff alarm (closed when alarm occurs) 3 9 Contact a for upper/lower temp. limit alarm (open when alarm occurs) 10 Common for upper/lower temp. limit alarm 4 11 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 12-14 Unused
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + 1 1 1 + 2 2 2 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + + 1 1 1 2 2 2 9 9 9 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
SET MODE Operation keys SD SG RD RS-232C COM S.STOP OUT1 OUT2 OUT3 OUT4 OUT5 100 to 240 VAC Power supply Output terminal Communication terminals Display detail Upper limit Functions (PRESCL, OFFSET, STOP, OUTPUT, INPUT, BACKUP, RS-232, UNIT) Mode indicators COUNT PRESET FUNC. BANK NO.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MVGQ CC Please consult with SMC separately for a BCD cable with connector.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MVGQ CC Please consult with SMC separately for a BCD cable with connector.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC MVGQ CC Please consult with SMC separately for a BCD cable with connector.
to 85 (No condensation and freezing) 14 to 140 (No condensation and freezing) 35 to 85 (No condensation and freezing) Serial communication Memory LED indicator Lock control Cable length (m) Cooling system Operating temperature range (F) Operating humidity range (%) Storage temperature range (F) Storage humidity range (%) Insulation resistance (M) Between the housing (radiation fin) and SG
1 SD+ 9 SD 5 SG 1 SD+ 9 SD 5 SG Circuit diagram Terminal resistance 120 Master This product This product (1st slave) (31st slave) Be sure to wire to the correct pin numbers according to the diagram.
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V Separate arrangements should be made for the BCD cable with connector.
Name of terminal block (LED) Note VF POWER RUN SD RD ERR RUN ERR TRD 10 1 24V 0V + + FG VFR L1 L2 SG L1 L2 SG 24V 0V VP7 Details It lights when transmission is normal and PLC is in the cperation mode. LED name LED name POWER RUN Details It lights when power is turned ON. RUN It lights when power is turned ON and slave stations are in normal operation.
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: (None), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: (None), Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)