H4 4/2.5 CJ-5H-4 With a fixed orifice (0.8) H6 6/4 CJ-5H-6 MH4 4/2.5 M-5H-4 Without fixed orifice MH6 6/4 M-5H-6 Dimensions (Dimensions other than below are the same as standard type.) Hose nipple Width across flats 8(7) (12) The above figure shows the 6/4 hose nipple mounting dimensions.
Function 2-Hexagon socket head set screw H4 4/2.5 CJ-5H-4 With a fixed orifice (0.8) H6 6/4 CJ-5H-6 MH4 4/2.5 M-5H-4 Without fixed orifice MH6 6/4 M-5H-6 Dimensions (Dimensions other than below are the same as standard type.)
The pressure sensor is shipped together with the product but does not come assembled. 12 ZNC Series Dimensions: 30, 40, 60 Basic type M5 x 0.8 thread depth 4 Air supply port PB1 M5 x 0.8 thread depth 4 Multi-port2, 4, 6 4 x H thread depth J R 16.5 Counterbore diameter P, depth Q Counterbore diameter P, depth Q 6.5 45 45 30 M5 x 0.8 thread depth 4 Air supply port PA1, 4 120 120 A Counterbore
PD12 *DI5H Input device selection 5H Any input device can be assigned to the CN1-19 pin. _ _ x x Torque control mode Device selection 03h Refer to table 5.10 in [Pr.
Tightening torque: 0.5 to 0.6 [N m] (4 to 5 [lb in]) Stripped length: 7 [mm] Mounting screw Screw size: M5 Tightening torque: 3.24 [N m] (28.7 [lb in]) Mass: 0.5[kg] (1.1[lb]) 11 11 11.
L11 L21 CNP3 3-M5 screw U V W PE Screw size: M4 Tightening torque: 1.2 [Nm] 42 0.3 Approx. 12 Approx. 6 Mounting hole process drawing 9 3 9.
_I A';'Plicable' ~q{~ Si~~\ Model 6 5, 10,15 <1<4/71>2.5 0 CJ-5H-4 10 5, ' 0. '5 15 5, ,a,15 Series CJP Construction/ Parts List Cautions Symbol =MQ OBlow out tubing and fittings fully befOfe use. f)lnstall air filters to supply clean air. 8 Use the provided hose nipple G M5 (orifice size ~O.8: ~ CJ-5H-4, CJ-5H-6. .0./ Panel mount type OLoad on the piston rod must be kept in line with
NPN1 + -100 to 100 FE PNP1 + 1) NPN1 + VA 1) PNP1 + VB 1 2) 2) M SI (kPa) 2) 3) (:psi) P 2) (99 10 ) 3) (1) VAVB (3) G 2m) W (2m) 4) (4) (5) (V ) 0 (M5x0.8) 5) K 1 3.2 () 4) 5) (1) VAVB 2 4 () 3 6 () 4 3.2 () 5 4 () 24 - No.ZQ-OM01401-B ZS-39-5G ZQ1-LW6-N-A 1) N NPN P PNP (1) 3 Assy ZQ1-PL11-A 4 Assy ZQ1-FC1-A 5 (10 ) ZQ1-FE2-A 6 ZQ1-CV 7 V VVQ1000-50A-C4 (1) 50A-M5
HRS-R Series 5.7 Run timer, stop timer function 5-15 HRX-OM-W058 Chapter 5 Display and setting of various functions Timer setting example Run timer Set to start after Now 1H 2H 3H 4H 5H 6H 7H 8H 3hours Stopped Operating Operating Stop timer Set to stop after 3 hours Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stopped Run timer Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer Set to start after
HRS-R Series 5.7 Run timer, stop timer function 5-15 HRX-OM-X027 Chapter 5 Display and setting of various functions Timer setting example Run timer Set to start after Now 1H 2H 3H 4H 5H 6H 7H 8H 3hours Stopped Operating Operating Stop timer Set to stop after 3 hours Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stopped Run timer Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer Set to start after
HRSH Series 5.7 Run Timer and Stop Timer Function 5-15 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions Timer setting examples Run timer Set to start 3 hours later Now 1H 2H 3H 4H 5H 6H 7H 8H Stopped Operating Starts operating Stop timer Set to stop 3 hours later Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stops operating Run timer + Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer
On the panel mounting style, use the CJ-5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed restriction) that is provided. If a different fitting must be used due to unavoidable circumstances, make sure to install a speed controller and use it by adjusting it to 500mm/s or less.
x 0.8 M5 x 0.8 M5 x 0.8 Rc (PT) 18 Rc (PT) 18 Fluid Air Action Double Acting Op.
M5 male x M5 male PAT 4/2.5 x M5 MS-5H-4 For piping nylon, soft nylon and polyurethane tubing For piping soft nylon tubing For piping polyurethane tubing Barb tee for soft tube 3.18/2.18 x M5 MS-5H-6 6/4 x M5 MS-5ATHU-3 3.18/2 x M5 Unrestricted 360 positioning and fastening around the stud axis Hose elbow For piping nylon, soft nylon and polyurethane tubing MS-5HLH-4 4/2.5 x M5 4/2.5 x M5
M5 male x M5 male PAT 4/2.5 x M5 MS-5H-4 For piping nylon, soft nylon and polyurethane tubing For piping soft nylon tubing For piping polyurethane tubing Barb tee for soft tube 3.18/2.18 x M5 MS-5H-6 6/4 x M5 MS-5ATHU-3 3.18/2 x M5 Unrestricted 360 positioning and fastening around the stud axis Hose elbow For piping nylon, soft nylon and polyurethane tubing MS-5HLH-4 4/2.5 x M5 4/2.5 x M5
2 7 21.5 18 14.5 2.5 2.9 3.2 M5x0.8 KJF23-M5 7 7 21 7.5 14.5 3/2.5 2.9 4 M3x0.5 KJS04-M3 1.5 8 18 15.5 14.5 1.4 1.5 4 M3x0.5 KJF04-M3 8 8 18 5.5 14.5 4 3.2 4 M5x0.8 KJS04-M5 2.5 8 20.5 17 14.5 4 2.6 4 M5x0.8 KJF04-M5 8 8 20.5 7.5 14.5 4 3.8 4 R(PT)1/8 KJS04-01S 3 9.8 21.5 17.5 14.5 4 5.3 6 M5x0.8 KJF06-M5 10 10 20 7 15.5 10 5.1 6 M5x0.8 KJS06-M5 2.5 10 21.5 18 15.5 4 3.2 6 R(PT)1/8 KJS06
plating) M-01H-6, M-5H-6 M-5HL-6, M-5HLH-6 7.
HRS Series 5.7Run timer, stop timer function 5-15 HRX-OM-S004 Chapter 5 Display and setting of various functions Timer setting example Run timer Set to start after 3hours Now 1H 2H 3H 4H 5H 6H 7H 8H Stopped Operating Operating Stop timer Set to stop after 3 hours Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stopped Run timer+ Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer Set to start after 2
HRS Series 5.7 Run Timer and Stop Timer Function 5-15 HRX-OM-W032 Chapter 5 Display and Setting of Various Functions Timer setting examples Run timer Set to start 3 hours later Now 1H 2H 3H 4H 5H 6H 7H 8H Stopped Operating Starts operating Stop timer Set to stop 3 hours later Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stops operating Run timer + Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer
Please reset. 5.7 Run timer, stop timer function HRSH Series 5-16 HRX-OM-R026 Chapter 5 Display and setting of various functions Timer setting example Run timer Set to start after 3hours Now 1H 2H 3H 4H 5H 6H 7H 8H Stopped Operating Operating Stop timer Set to stop after 3 hours Now 1H 2H 3H 4H 5H 6H 7H 8H Operating Stopped Stopped Run timer+ Now 1H 2H 3H 4H 5H 6H 7H 8H Stop timer Set to