For (Built-in One-touch fitting) C4 N3 Directional Control Valves Air Grippers Modular F.
Symbol Port size Applicable series One-touch fitting for 5/32" N3 One-touch fitting for 1/4" N7 SX3000 Mixed M One-touch fitting for 5/32" N3 One-touch fitting for 1/4" N7 SX5000 One-touch fitting for 5/16" N9 Mixed M In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
SX VK L C3 (3.2) C4 (4) C6 (6) M5 (M5 thread) VZ C6 (6) kit VF VFR N1 (1/8) N3 (5/32) N7 (1/4) N7 (1/4) VP7
ZB-OM00201-B (14) Pressure switch assembly for vacuum If only the lead wire with connector is required order part number ZS-39-5G.
Q2 +COM 30.30.4 4 L L 5 DC24V LO L 6 DC12V M M 5 MO M 5 4300 5MMO 6 B 6() 9 - No.ZB-OM00301 / kPa / P1 0-101 15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4
N3: 5/32" N7: 1/4" N9: 5/16" NM: Mixed sizes The top ported elbow is LN and the bottom ported elbow is BN. For NM, specify it on the manifold specification sheet.
C4 N3 /SS5YJ3-S32Stations -M5, Type S32 Manifold: Side Ported Single solenoid coil is on same side as the A,B port.
C4 N3 /SS5YJ3-S32Stations -M5, Type S32 Manifold: Side Ported Single solenoid coil is on same side as the A,B port.
C4 N3 Type S42R Manifold: Side Ported (Pilot valve is on the A port side) / SS3YJ3-S42RStations -M5, Grommet (G) For M5 For (Built-in one-touch fitting) C4 N3 M5 x 0.8 (X port) 8 8 1/8 (P, R port) 5 5 20.5 12 52.9 [55.1] Approx. 300 (Lead wire length) 30.7 X X 36 17.5 35.9 R P 2-4.5 (For mounting) 11.4 Manual override 18.5 (Pitch) P=10.5 (4.4) L1 L2 4 8.5 (Station n) (Station 1) (Station
Part number of the lead wire with connector: ZS-39-5G A ZB1 SE1 9 Compact Vacuum Unit Series ZB Dimensions: Single Unit (inch) 10 11 20 21 (inch) K1 Q1 L(O) M(O) ZB A B C2 C4 N1 N3 L2 L4 LN1 LN3 Port type 0.16 0.3 0.29 0.3 0.33 0.33 0.33 0.33 3.09 3.22 3.22 3.22 3.26 3.26 3.26 3.26 Ejector/Vacuum pump system Silencer exhaust, With supply valve/release valve, Without sensor/switch Manual override
(Manifold base) SYJ5120-5G-M5 2 pcs. (Valve) SYJ5000-21-1A 1 pc. (Blanking plate assembly) SS5YJ5-43-03-C4 1 pc. (Manifold base) SYJ5140-5LZ 1 pc. (Valve) SYJ5240-5LZ 1 pc. (Valve) SYJ5000-21-1A 1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
(Example) SS3YJ5-20-03 . 1 set (manifold base) SYJ512-5LZ-M5 . 2 sets (valve) SYJ500-10-1A . 1 set (blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (manifold base) SYJ514R-5G . 2 sets (valve) SYJ500-10-3A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: None, Port Size: M5 (Body Ported M5X0.8)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Pipe Port Type: M, Port Size: M5, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot
SY3140-5G-Q . 3 sets (Single solenoid part no.) SY5140-5G-Q . 2 sets (Single solenoid part no.)
SY3140-5G . 2 sets (Single solenoid part no.) SY3240-5G . 2 sets (Double solenoid part no.)
Grease pack GR-X-005 (5g) Caution 1. Be careful of the snap ring springing out.
200 5g 230 5g 270 5g 290 5g 3505g Air IN/OUT Connection Rc3/8 Rc1/2 Rc3/4 Rc1 Acceesory (Hexagon nipple) R3/8 R1/2 R3/4 R1 Drain Connection (Outside Diameter of Tubing) 10mm Color Panel: Urbanwhite1Base:Urbangray2 Weight 18kg 22kg 23kg 27kg 28kg 46kg Note1: The data for m3/ (ANR) is referring to the conditions of 20C, 1atm . pressure & relative humidity of 65%.
Net weight Part No. 5g GR-L-005 10g GR-L-010 150g GR-L-150 C a u t i o n 1 When replacing mounting brackets, use socket wrench. Using other tools would cause deformation of nuts and inferior workability. Refer to the following table for sockets used.