SMC Corporation of America
Elite Part Number Search
Search Results "SYJ3143-5HZ"

The ionizer generates ion at the preset frequency. 0: 1Hz 1: 3Hz 2: 5Hz 3: 10H 4: 15Hz 5: 20Hz 6: 30Hz 7: 60Hz Operation with pulse + Ion Ion (e.g.) Charged workpiece: Charged in negative Static neutralization is completed (6) Wiring of Power supply cable Connect the special power supply cable to the unit.

Standard Specifications Standard Specifications Type of seal Metal seal Rubber seal Fluid Air, Inert gas Air, Inert gas Max. operating pressure 100 psi (0.7MPa) High pressure type 113 psi (0.8MPa) Min. operating pressure 14 psi (0.1MPa) 21 psi (0.15MPa) Valve specifications Solenoid specifications Note 1) Note 1) Ambient and fluid temperature 14 to 122F 14 to 122F Max. operating frequency 20Hz 5Hz

Display of frequency IZT40IZT41 1Hz 3Hz 5Hz 8Hz 10Hz 15Hz 20Hz 30Hz DC DC IZT42 0.1Hz 0.5Hz 1Hz 3Hz 5Hz 8Hz 10Hz 15Hz 20Hz 30Hz Default frequency setting is 30 Hz. Set the optimum frequency depending on the operating environment and installed distance. 4-4-4. Offset voltage adjustment mode Offset voltage is adjusted before shipment.

Display of frequency 1Hz 3Hz 5Hz 8Hz 10Hz 15Hz 20Hz 30Hz DC DC Default frequency setting is 30 Hz. Set the optimum frequency depending on the operating environment and installed distance. 4-4-4. Offset voltage adjustment mode Offset voltage is adjusted before shipment.

No 0-1Hz 1-3Hz 2-5Hz 3-8Hz 4-10Hz 5-15Hz 6-22Hz 7-33Hz 8-5 6 7 ; < = : 9 8 Generate only plus ion 9-Generate only minus ion 6. Selection and setting of equipment 6-1. Sensing DC mode 1. selection of bar length Select the length applicable to work size base on [2. static charge elimination area of 7-1. static charge elimination characteristics (reference)] 2.

SMC endurance test conditions Normal temperature (Room temperature) 5Hz Rated voltage Max. operating pressure The valve was opened and closed, checked for internal and external leakage and proper operation. We confirmed that the product satisfies the product specifications up to 2,000,000 cycles. 16 XSA-OMS0001-A 7. Troubleshooting This section summarizes troubleshooting the product.

Fluid Air Operating pressure range 0.2 to 0.5MPa Internal pilot type Ambient and fluid temperature 5 to 50C Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Push-turn slotted locking type Pilot valve individual exhaust type, Main valve/pilot valve common exhaust With vacuum pressure gauge Pilot exhaust type Lubrication

Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz

ZSE1-00ZSM1-0 Vacuum pressure switch 30 m PE (Polyethylene) Suction filter Valve Specifications How to operate Pilot type NBR poppet 3 mm2 Compact and lightweight 15.5 mm width, 400 g (full system) Main valve Effective area Cv factor Operating pressure range Electrical entry Max. operating frequency Voltage Power consumption 0.17 0.25 to 0.7 MPa Plug connector, Grommet (available on DC) 5Hz

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override 150/30 m/s2 Shock/Vibration resistance (2) Dust proof Enclosure 12V, 24V DC and 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B or equivalent Coil insurance 1W DC (42mA), 0.5W DC (21mA

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override 150/30 m/s2 Shock/Vibration resistance (2) Dust proof Enclosure 12V, 24V DC and 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B or equivalent Coil insurance 1W DC (42mA), 0.5W DC (21mA

Specifications Metal seal Seal Rubber seal Air, lnert gas Fluid Air, lnert gas 0.7MPa (High pressure type: 1.0MPa) Max. operationg pressure 0.15MPa Single Double 2 position Min. operating pressure 0.1MPa only for VQZ3000, 3 position 0.15MPa Valve specifications 0.1MPa 3 position 0.2MPa (1) (1) 10 to 50C Ambient and fluid temperature 10 to 50C SY Single Double Max. operating frequency 20Hz 5Hz

Air, lnert gas Air, lnert gas Fluid 0.7MPa (High pressure type: 1.0MPa) 0.7MPa Max. operating pressure 0.15MPa Single Double 2 position Max. operating pressure 0.1MPa only for VQZ3000, 3 position 0.15MPa Valve specifications Solenoid specifications 0.1MPa 3 position 0.2MPa (1) (1) 10 to 50C Ambient and fluid temperature 10 to 50C SY Single Double 2 position Max. operating frequency 20Hz 5Hz

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override (2) 150/30 m/s2 Shock/Vibration resistance Dust proof Enclosure 12V, 24V DC 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B Coil insurance 1W DC (42mA), 0.5W DC (21mA) 24V DC 1W DC (

ZSE1-00ZSM1-0 Vacuum pressure switch 30 m PE (Polyethylene) Suction filter Valve Specifications How to operate Pilot type NBR poppet 3 mm2 Compact and lightweight 15.5 mm width, 400 g (full system) Main valve Effective area Cv factor Operating pressure range Electrical entry Max. operating frequency Voltage Power consumption 0.17 0.25 to 0.7 MPa Plug connector, Grommet (available on DC) 5Hz

Fluid Air Operating pressure range Internal pilot type 0.2 to 0.5MPa (29 to 72 psi) 5 to 50C (41 to 122F) Ambient and fluid temperature Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Slotted locking type With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust

Type of valve actuation Air Fluid 0.2 to 0.5MPa Operating pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type

Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz

Function: 1 (2 Position Single), Piping: 4 (Base Mounted 5 Port), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m)

Function: 1 (2 Position Single), Piping: 4 (Base Mounted 5 Port), Exhaust: 3 (Common), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m)