/60 Hz L plug 25 2500 mm LN Without lead wire 2 200 VAC 50/60 Hz connector 30 3000 mm LO Without connector 110 VAC 50/60 Hz 50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.

SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

/60Hz) 2* 200VAC (50/60Hz) 3* 110VAC (50/60Hz) 4* 220VAC (50/60Hz) 5 24VDC 6 12VDC 9* Others Courtesy of Steven Engineering, Inc. !

Manifold Specifications SV1000 SV2000 SV3000 SV4000 Applicable series Manifold type 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) Max. number of solenoids Tie-rod base manifold Common SUP, EXH 20 stations 32 points 1(P), 3/5(E) port C8, N9 C3, C4, C6 N1, N3, N7 C10, N11 C4, C6, C8 N3, N7, N9 C12, N11 C6, C8, C10 N7, N9, N11 C12, N11, 03 C8, C10, C12 N9, N11, 02, 03 Port size 4(A)

25 30 50 Note) Available in units of 10 pieces.

C4 N3 /SS5YJ3-S32Stations -M5, Type S32 Manifold: Side Ported Single solenoid coil is on same side as the A,B port.

Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.

Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It

K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.

With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN

With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN

/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.

/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.

S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. SOL.

220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.

/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] With surge voltage suppressor (Non-polar type) T With light/surge voltage suppressor (Non-polar type) With surge voltage suppressor (Non-polar type) Power saving circuit is not available for W type.

B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. SOL.

Note 4) Refer to page 50 for details on enclosure.

Coil voltage Configuration Note 2) VQ1000 VQ2000 1 2 3 4 5 6 VQ0 100V AC (50/60Hz) 2 position single 1 2 3 4 5 200V AC (50/60Hz) 2 position double (latching) 110V AC (50/60Hz) Electrical entry (2) (1) 3 position closed center 220V AC (50/60Hz) 24V DC 12V DC Grommet (Except for double (latching) and AC.)