/60Hz) 2* 200VAC (50/60Hz) 3* 110VAC (50/60Hz) 4* 220VAC (50/60Hz) 5 24VDC 6 12VDC 9* Others Courtesy of Steven Engineering, Inc. !
/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] With surge voltage suppressor (Non-polar type) T With light/surge voltage suppressor (Non-polar type) With surge voltage suppressor (Non-polar type) Power saving circuit is not available for W type.
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
Specification SV2000 SV1000 SV4000 SV3000 Applicable series Manifold type Tie-rod base manifold 1(P: SUP)/3, 5(E: EXH) type Common SUP, EXH Valve stations (maximum) 20 stations Max. number of solenoids 32 points Port size 1(P)/3, 5(E) port C10, N11 C8, N9 C12, N11, 03 C12, N11 C4, C6, C8 N3, N7, N9 C3, C4, C6 N1, N3, N7 C8, C10, C12 N9, N11, 02, 03 C6, C8, C10 N7, N9, N11 4(A)/2(B) port Flow
Note 4) Refer to page 50 for details on enclosure.
10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50,7 5, 100, 125, 150 *90and 91-series MXQ6 products do not have shock absorbers.
Applicable cable O.D. 3.5 to 7 Station n L1 L2 3 80 68 Station 20 403 391 6 137 125 8 175 163 10 213 201 Station 2 61 49 4 99 87 5 118 106 7 156 144 9 194 182 11 232 220 12 251 239 13 270 258 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 4-4-50 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ700 N7 N9 C6 C8 [ ] for AC Type 42R Manifold: Side Ported/SS3YJ7-42RStations
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
wire Without connector 50 60 2 200 VAC Hz M M plug connector 50 60 110 VAC Hz [115 VAC Hz] MN MO M8 connector Without connector cable W0 3 50 60 50 60 50 60 4 220 VAC Hz [230 VAC Hz] Note) For connector cable of M8 connector, refer to page 225.
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Bore size 16 20 25 32 40 50 63 16 20 25 32 40 50 53 Recommended length Part No.