(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.
Applicable blank plate assembly SY100-77-1A P R 20 stations VP 20 R port M5 X 0.8 P port M5 X 0.8 VG VP Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold. S41 Type How to Order Applicable solenoid valve (1) SS3Y1 S41 05 M3 VQ SY114-l SY114A-l SY124-l SY124A-l Stations A port size M3 M5 M3 X 0.5 M5 X 0.8 VQZ 2 stations 02 ... ...
List part numbers of the installed valve and option in required station location separately under manifold part number. 4-2-7 8 Series V100 Common SUP/Common EXH Type S41 How to Order Applicable solenoid valve Note) VV100 S41 05 M5 V114V114AV124V124AStations 2 port size 02 M5 M5 x 0.8 2 stations 2 Applicable blank plate assembly V100-77-1A 1 20 20 stations 3 2 1 port M5 x 0.8 3 port M5 x
x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 N.C.
pilot Flow Characteristics Flow characteristics Effective area (mm2) Port size 1 2 (P A) 2 3 (A R) Manifold C [dm3/(s bar)] 1(P), 3(R) Port 2(A) Port b Cv C [dm3/(s bar)] b Cv Body ported for internal pilot M3 x 0.5 0.9 Type SS3YJ3-20 SYJ32 M5 x 0.8 Type SS3YJ341 S41 SYJ34 M3 x 0.5 M5 x 0.8 1.5 0.17 0.36 0.3 0.17 Type SS3YJ3-42-M5 Base mounted for internal pilot M5 x 0.8 0.31 0.33 0.32
Flow characteristics Effective area (mm2) Port size 1R2 (PRA) 2R3 (ARR) Manifold C [dm3/(s bar)] 1(P), 3(R) Port 2(A) Port b Cv C [dm3/(s bar)] b Cv Body ported for internal pilot M3 x 0.5 0.9 Type SS3YJ3-20 SYJ32 M5 x 0.8 Type SS3YJ341 S41 SYJ34 M5 x 0.8 M3 x 0.5 1.5 0.17 0.36 0.3 0.17 Type SS3YJ3-42-M5 Base mounted for internal pilot 0.31 0.33 0.32 0.35 0.075 0.086 0.079 0.082 0.32 0.33
4" one-touch fitting) M5 0.8 1/8 NPTF Port size M5 0.8 A port X port Note1) M5 0.8 M5 0.8 M5 0.8 Body ported type SYJ5 2/SYJ5 2R 3.4 (0.19) Note 2) Valve effective area mm2(Cv) M5 : 3.3 (0.18) 1/8 : 4.8 (0.27) N3T, N7T: 3.8 (0.21) Base mounted type SYJ5 4/SYJ5 4R M5 : 3.8 (0.21) 1/8 : 4.7 (0.26) Note 1 : Only for external pilot Note 2 : Value when used on a manifold Proper Combinations of
on same side of A and B port 1 station Nil P port: Rc 1/8 A port: M5 x 0.8 B port: M5 x 0.8 Thread type R port: Rc 1/8 20 Solenoid on same side of A and B port 20 stations Type S41 Nil F N T Rc S Type VK334 Type VK3140 Port size G M5 M5 x 0.8 C4 4 cassette NPT P port: Rc 1/8 NPTF R port: Rc 1/8 B port: M5 x 0.8 A port: M5 x 0.8 Type 42: Base mounted (A, B port side ported) How to Order Applicable
Applicable blanking plate assembly VK3000-7-1A 01 1 station Solenoid on opposite side of A and B port P port: Rc 1/8 A port: M5 x 0.8 B port: M5 x 0.8 Nil R port: Rc 1/8 Thread type Type S41 20 20 stations Solenoid on same side of A and B port Type VK334 Type VK3140 P port: Rc 1/8 R port: Rc 1/8 S Nil Rc Port size Q CE-compliant Nil CE-compliant F N T G M5 M5 x 0.8 C4 4 cassette NPT B port
Type S41 Nil F N T Rc S Type VK334 Type VK3140 Port size G M5 M5 x 0.8 C4 4 cassette NPT P port: Rc 1/8 NPTF R port: Rc 1/8 B port: M5 x 0.8 A port: M5 x 0.8 Type 42: Base mounted (A, B port side ported) How to Order Applicable solenoid valve VK3140 VK334 Type VK3140 VV5K3 42 05 01 Type VK334 Applicable blanking plate assembly VK3000-7-1A Valve stations Solenoid direction 01 1 station Solenoid
(DIN 22.7) 21.5 (DIN 22.7) 8.5 103.2 [107.6] 16.5 23.5 R P R R P R A A A A A 87.2 [91.6] 33 47 44.2 [46.4] 22.1 (DIN 23.3) 43.6 [45.8] B B B B B 2.5 1/8 (P, R port) (Pitch) P = 16 Manual override 21 (Station n) (Station 1) Built-in speed controller (Light/surge voltage suppressor) 48.6 [55.6] + + + + + 33.2 12 20 M5 x 0.8 (A, B port) 24 Max. 13.5 43.5 (Pitch) P = 16 23 L plug connector (
VZA2221-M5 VZA2321-M5 VZA2421-M5 VZA2141-1-01 VZA2141-2-01 VZA2241-1-01 VZA2241-2-01 VZA2341-1-01 VZA2341-2-01 VZA2441-1-01 VZA2441-2-01 Single Double Closed center Exhaust center 0.60 0.60 0.56 0.60 0.43 0.43 0.15 0.20 0.15 0.15 0.13 0.15 0.59 0.59 0.59 0.59 0.30 0.30 0.22 0.22 0.15 0.15 0.14 0.14 Body ported Base mounted (With sub-plate) 2 position Body side M5 x 0.8 3 position M5 x 0.8
Note 3) Model No. for 5 port base mounted type without sub-plate is SYJA540. 1478 4/5 Port Air Operated Valve SYJA5000 Series Dimensions/Body Ported Dimensions/Base Mounted 2 position single: SYJA5120-M5(-F) 2 position single: SYJA5140-01 41.5 2 x 4.3 (For mounting) 19.5 M5 x 0.8 (Pilot port) 37.5 4 M5 x 0.8 (Pilot port) 11 B A 5 16 A B SYA 1 1 24 10 2 x 2.6 (For manifold mounting) M5 x 0.8
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 16 Stations, A B Port Size: C4 (ø4 One-touch Fitting)
Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 16 Stations, A B Port Size: ø4 One-touch Fitting, P R Port Thread: -
48(22) Base mounted 2 position double SYJA3240-M5 51(25) 1.8 (0.1) 3 position exhaust center SYJA3340-M5 M3 X 0.5 M5 X 0.8 54 (28) 3 position exhaust center SYJA3440-M5 3 position pressure center SYJA3540-M5 2 position single SYJA3130 22 4 port base mounted (For manifold) 2 position double SYJA3230 25 M3 X 0.5 (1) 1.2 (1) M3 X 0.5 3 position exhaust center SYJA3330 (0.067) M5 X 0.8 3 position
M5 x 0.8 (Piping port) (Piping port) With fiflter (80 mesh) 21.5 R1 P 8.5 6 6 2-1.8 (Bleed port) 17 17 15 R2 21 With fiflter (80 mesh) 24 32 45.5 3 position closed center/exhaust center/pressure center SYJA5 20-M5 3 position closed center/exhaust center/pressure center SYJA5 40-01 3 4 5 3 4 5 28 2-4.3 2-M5 x 0.8 2-M5 x 0.8 37.5 23 (Pilot port) (For mounting) (Pilot port) A B 11 20 23 5 3
Common SUP/Common EXH Common SUP/ Individual EXH Type 40 (VV5K3-40): Base mounted (A, B port bottom ported) Type 20 (VV5K3-20): Body ported (A, B port top ported) Type 42 (VV5K3-42): Base mounted (A, B port side ported) Type 41 (VV5K3-41): Base mounted (A, B port side ported) Type S41 Type S42 (VV5K3-S41) (VV5K3-S42) Type 21 (VV5K3-21): Body ported (A, B port top ported) 12 VK300-OMH0002-
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 7 Stations, A B Port Size: M5 (Base Mounted M5X0.8)
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 10 Stations, A B Port Size: M5 (Base Mounted M5X0.8)