Seal material Fluororubber Ambient temperature range With auto switch: 10C to 60C (No freezing)*1 Without auto switch: 10C to 70C (No freezing) Specifications other than above and external dimensions Same as standard type Symbol -XC35 With Coil Scraper 7 It gets rid of frost, ice, weld spatter, cutting chips adhered to the piston rod, and protects the seals etc.
Seal material Fluororubber Ambient temperature range With auto switch: 10C to 60C (No freezing)*1 Without auto switch: 10C to 70C (No freezing) Specifications other than above and external dimensions Same as standard type Symbol -XC35 With Coil Scraper 8 It gets rid of frost, ice, weld spatter, cutting chips adhered to the piston rod, and protects the seals etc.
B Z + Stroke DB DX DD 90 B 4DT A DS DH 4DR DB DU DO DO DC DE DU DL Rotation (mm) No.
The cylinder seals are changed to a heat resistant (to 110C) material, for use under severe temperature conditions which exceed the standard specifications of 10C to +70C. Standard part no.
D -DIN terminal DS -DIN terminal with surge voltage suppressor DL -DIN terminal with light DZ -DIN terminal with surge voltage suppressor and light DO-For DIN terminal (without connector) Connector Refer to the Table (1) for the available combinations between each electrical option and rated voltage.
G -Grommet GS-With grommet surge voltage suppressor C-Conduit G-Grommet C-Conduit T -With conduit terminal TS -With conduit terminal and surge voltage suppressor TL -With conduit terminal and light TZ -With conduit terminal, surge voltage suppressor and light D -DIN DS -DIN with surge voltage suppressor DL -DIN with light DZ -DIN with surge voltage suppressor and light DO-For DIN (without
Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Rubber bumper, Air cushion Not required (Non-lube) JIS 2nd class Ambient and fluid temperature Cushion Lubrication Thread tolerance Stroke tolerance CL Non-locking and locking styles are standard for manual release. +1.4 0 MLGC Rubber bumper Air cushion 50 to 750mm/s 50 to 1000mm/s Piston speed CNA Basic
Furthermore, when controlling for low speed or controlled output, use clean air (atmospheric pressure dew point temperature of 10C). Installation of a mist separator (filtration degree 0.3m or less) is also recommended. 3. Use a metal seal type when using solenoid valves for cylinder actuation.
Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Rubber bumper, Air cushion Not required (Non-lube) JIS 2nd class CL Ambient and fluid temperature Cushion Lubrication Thread tolerance Stroke tolerance MLG +1.4 0 CNA Rubber bumper Air cushion 50 to 750mm/s 50 to 1000mm/s Piston speed CNG Basic, Axial foot, Front flange, Rear flange, Single clevis, Double
Note 2) Dew point is -10C or below. Note 3) 50cSt or less 38 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO Direct Air Operated 2 Port Valve For air, gas, vacuum, water, oil Series VXA21/22 Air Purge Models/Valve specifications Normally Closed (N.C.)/Normally Open (N.O.)
Unless otherwise indicated in the specifications for each valve, operation is possible to 10C, but appropriate measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 6. Operation for air blowing When using a solenoid valve for air blow, use an external pilot type.
Specifications Ambient temperature 10C to 100C (No freezing) Seal material Fluororubber MXQ X2128 Standard model no. Grease Heat-resistant grease (GR-F) Heat-resistant specification Applicable adjuster type Metal stopper Specifications other than the above are the same as the standard type.
MB MB MB1 Specifications Ambient temperature range 10C to 120C Bore size 40, 50, 63, 80, 100 Warning CA2 Precautions Seal material Fluororubber CS1 Be aware that smoking cigarettes etc. after your hands have come into contact with the grease used in this cylinder can create a gas that is hazardous to humans.
Operation at low temperature The valve can be used in an ambient temperature up to 10C. However, take measures to prevent freezing or solidification of impurities, etc. When using valves for water application in cold climates, take appropriate countermeasures to prevent the water from freezing in tubing after cutting the water supply from the pump, by draining the water, etc.
W1 B DX Z + Stroke DDH10 hole 90 B 4-DT B DS A DH DF DU DU DL DA 4-DR DO DO DC DE Rotating Angle Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 50 63 80 100 Part no.
W1 B DX Z + Stroke DDH10 hole 90 B 4-DT B DS A DH DF DU DU DL DA 4-DR DO DO DC DE Rotating Angle Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 50 63 80 100 Part no.
If the socket will be used again, first spread the hook outward. 10 No.SYJ300-OMV0001 SYJ Series Specific Product Precautions 3 DIN Terminal With surge voltage suppressor (DS) With light/surge voltage suppressor (DZ) DIN terminal has no polarity. M8 Connector Standard type (with polarity) Be sure to read this before handling the products.
Low temperature operation Unless otherwise indicated in the specifications for each valve, operation is possible to -10C, but appropriate measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 4. Operation for air blowing When using solenoid valves for air blowing, an external pilot type should be used.
@ruumoer Axial piping lcentEllzed plplnql Double acting Single rod @12, o1615 to 30 6N, a2g5 lo 50 o32, o40/5 to 1oo o50 lo @10C/10lo 100 Sh9leacting Sp ng retum/extend o l 2 l o o 4 o l 5 . l O o5U1O,m @options High tempeture 1 2 l o 1 0 0 1 2 l o 4 A Low speed (10 lo 50mm/s) l2 to 100 Lovr/ speed cylinder (5 to 5omm/sl 12 to 100 Heal resislanl aulo sw lch 16 to 63 Heavy duty scraper 20
VK3000 series can be used down to -10C. Connection thread Proper tightening torque (Nm) Rc1/8 3~ 5 5 VK300**-OMH0002-C VK300/3000 Series Precautions for 3/5 Port Solenoid Valve 3 Be sure to read before handling. Piping Air Supply 4. Piping to products 1. Type of fluids Warning Caution When piping to a product, avoid mistakes regarding the supply port, etc.