Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: M, Body Options: With lock mechanism, with cancel cap, with lever detection switch
Bore Size: 20mm, Port Thread: 20mm Bore: M Thread; 32-80mm Bore: Rc Thread, Stroke: 15mm, Action: T (Single Acting Spring Extend), Roller Material: L (Resin), Option: DC (Locking Mechanism, Cancel Cap), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Bore Size: 20mm, Port Thread: 20mm Bore: M Thread; 32-80mm Bore: Rc Thread, Stroke: 15mm, Action: D (Double Acting), Roller Material: M (Rolled Steel), Option: DC (Locking Mechanism, Cancel Cap), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Bore Size: 20mm, Port Thread: 20mm Bore: M Thread; 32-80mm Bore: Rc Thread, Stroke: 15mm, Action: D (Double Acting), Roller Material: L (Resin), Option: DC (Locking Mechanism, Cancel Cap), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: M, Body Options: With lock mechanism, with cancel cap, with lever detection switch
RSH20 RSH32, RS2H50/63/80 2. Disassembly/Reassembly Caution Disassemble and assemble the cylinder in a clean area. Perform on a clean cloth. When disassembling the cylinder, loosen the hexagon socket head cap screws (20: 2pcs., 32 to 80: 4pcs.) with a hexagon wrench.
Refer to page 66 for details. 33 Heavy Duty Stopper Cylinder 20, 32 50, 63 90-RSH/RS1H Series How to Order Piping direction Positional relationship of lever and port Port 90-RSH20 Flange side Direction of transfer Nil Nil Direction of transfer 90-RSH32 Port Cylinder stroke 15 20 Bore size 20 32 15 mm (90-RSH20) 20 mm (90-RSH32) 20 mm 32 mm Heavy Duty Stopper Cylinder 20, 32 M9BWL 32 20 D
Bore Size: 20mm, Port Thread: 20mm Bore: M Thread; 32-80mm Bore: Rc Thread, Stroke: 15mm, Action: Double Acting, Roller Material: Resin, Option: Locking Mechanism, Cancel Cap & Lever Detection Switch, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Special function Electrical entry Indicator light Wiring (Output) In-line Perpendicular 0.5 (Nil) 3 (L) DC AC 5 (Z) MHT Type 3-wire (NPN) 3-wire (PNP) 24 V MHY M9NV M9N Solid state switch 5 V IC circuit 12 V M9PV M9P Standard MHW Relay, PLC Grommet Yes M9BV M9B 2-wire 12 V Water resistant (2-color indication) MRHQ F9BA Lead wire length symbols: 0.5 m Nil (Example) M9B 3 m L (Example) M9BL
Connection and Electrical Circuit Caution Both DCs have no polarity, and then connect each lead wire with the power source side.
Heavy duty stopper cylinder, Double acting and single acting available, Bore sizes: 20mm to 80mm, Stroke range: 15mm to 40mm, Auto switch capable, RESIN ROLLER, RSH20, ACTUATOR, RSH STOPPER CYLINDER, H1, 20MM RSH PART, .00235 lb
Heavy duty stopper cylinder, Double acting and single acting available, Bore sizes: 20mm to 80mm, Stroke range: 15mm to 40mm, Auto switch capable, SHOCK ABSORBER (RSH20), ACTUATOR, RSH STOPPER CYLINDER, H2, 20MM RSH KIT/ACCESSORY, .03970 lb, ModelBore size (mm)ActionStyle of rod endFluidProof pressureMax. operating pressureAmbient and fluid temperatureLubricationCushionStroke length
The shock absorber used in the RSH20/32 series is a low-resistance type shock absorber, and it is available as a special order. Contact your local SMC sales office for further information about this custom shock absorber.
The RSQ series is a fixed-height stopper cylinder with proven endurance and low breakaway characteristics. The RSG series is an adjustable mounting height stopper cylinder. It can be raised or lowered according to the distance required to stop the work piece. The RSH heavy-duty stopper cylinder is specially designed for use on conveyor lines or other applications requiring an external stopping
The RSQ series is a fixed-height stopper cylinder with proven endurance and low breakaway characteristics. The RSG series is an adjustable mounting height stopper cylinder. It can be raised or lowered according to the distance required to stop the work piece. The RSH heavy-duty stopper cylinder is specially designed for use on conveyor lines or other applications requiring an external stopping
The positioner cannot work independently and is used as a part of loop including actuating equipment such as a valve, actuator and DCS. Therefore, it should be noted that the described characteristic values may vary depending on the loop conditions.
The positioner cannot work independently and is used as a part of loop including actuating equipment such as a valve, actuator and DCS. Therefore, it should be noted that the described characteristic values may vary depending on the loop conditions.
It is recommended that the earthing of the input cable shield be carried out from the DCS end only. M20 x 1.5 cable gland, or 1/2 NPT cable gland (U, E2) Connect the conductors to the terminal strip as shown in Fig. 10. The position transmitter is connected to 2-pole terminal PT as shown in Fig. 9. The position transmitter needs an external power supply.
$n &1 OPTIONAI TEFMINAIILOC( nel: AXT 622 5rl Moontlng Scr.rc Inclu&d (2'ls 4r8) 13 DIRECTIO}IAL AIR VALVE INTERFACE REGULATORS S TOP V A LV E & DCS OLE NO SERIES NVS 4,14 Intertace Regulalors Opratlon: OE|lEAAL C-ylnclff pur is contlolld by rn adjustned knob loctld on fia .gl.llalor block, Sl6ct tha rcquircd prcs. surc and push tlla knob unlil il locks.
How to Order NCJ2 NCDJ2 I T Built.in magnet a Type Number of auto switches Mounting style 2 Dcs. Auto switch @ * see cataog N301 brava able au10 switches. Bore sizel E6';_l IE to" I I E t e " J Port location on head covqr stroke (l00ths o Standard Action S nqle aclinq sprina return S nqle aclina sprina exlend 'See Cala o!