SMC Corporation of America
Elite Part Number Search
Search Results "RS2H63TNA-30DM-SP-M9BM"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Bore: 63mm, Port Thread: TN (NPT), Piping: A (Axial Direction), Stroke: 30mm, Action: D (Double Acting), Roller Material: M (Carbon Steel), Option: S (Lever Detection Switch), Port and Lever Position: 0°, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Bore: 63mm, Port Thread: NPT, Piping: Axial Direction, Stroke: 30mm, Action: Double Acting, Roller Material: Carbon Steel, Option: Lever Detection Switch, Port and Lever Position: 0°, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: -, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Bore: 50mm, Port Thread: Rc, Piping: Flange Side, Stroke: 30mm, Action: D (Double Acting), Roller Material: M (Carbon Steel), Option: S (Lever Detection Switch), Port and Lever Position: P (90° Clockwise)

Bore: 50mm, Port Thread: TN (NPT), Piping: Flange Side, Stroke: 30mm, Action: D (Double Acting), Roller Material: M (Carbon Steel), Option: S (Lever Detection Switch), Port and Lever Position: P (90° Clockwise)

Bore: 50mm, Port Thread: Rc, Piping: Flange Side, Stroke: 30mm, Action: Double Acting, Roller Material: Carbon Steel, Option: Lever Detection Switch, Port and Lever Position: 90° Clockwise, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Bore: 50mm, Port Thread: NPT, Piping: Flange Side, Stroke: 30mm, Action: Double Acting, Roller Material: Carbon Steel, Option: Lever Detection Switch, Port and Lever Position: 90° Clockwise, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Item Setting range Descriptions Factory default DI PV, DI SP, N/A, TEMP PV, TEMP SP, FLOW PV, FLOW SP, PRESS Used to specify the type of analog output signal. DI PV, DI SP is displayed only if the DI control kit (optional) is provided.

Item Descriptions Setting Range Factory Default Store the TEMP SP and FLOW SP value with serial communication.

ZX1-DR1 SP How to Order Unit for Replacement ZCUK (1) Valve unit (4) Adsorption confirmation switch unit Refer to page 872 for details.

Item Setting range HRZL : -20.0 to 40.0C HRZ-L2 : 10.0 to 40.0C HRZ-H : 20.0 to 90.0C HRZ-W : -20.0 to 90.0C 1 TEMP SP 2 FLOW SP 10 to 40LPM(2.6 to 10.6GPM) FLOW SP is only indicated on HRZ010-W*S and Setting is available.

Item Setting range 1 TEMP SP 20.0 to 90.0C 2 FLOW SP 10 to 40LPM(2.6 to 10.6GPM) FLOW SP is only indicated on HRW-HS and Setting is available*2. [Tips] See Mode Selection screen in Chapter 5 on page 5-6 for details on SER REMOTE (*1).

(Solenoid valve: 24 VDC, M plug connector type) ZP SP How to Order Refer to page 940 for further part no. information.

Adsorption surface area Closeup picture This value represents the average diameter when air vents are converted to a circle. 1 mm Body part Aluminum casted Adsorption surface (Sintered metallic element) Stainless steel 751 Adsorption Plate SP Series RoHS SP SP How to Order ZCUK AMJ SP 30 1 1 AFJ Sintered metallic element particle diameter Adsorption Plate AMV 30 0.3 standard ZH -X185 Adsorption

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.