Insert the radio noise filter (FR-BIF (Mitsubishi Electric Corporation)) on the power cables (Input cables) of the driver. 2.
FS(a) FS(b) Fr Reduced backlash Even with a single rack design, the use of a special construction minimizes backlash. CRJ1 CRJ05 Model 30 25 Fr Allowable load (N) 25 20 FS(a) 25 20 FS(b) 6 5 Pinion gear Output shaft size (mm) Stopping the pinion gear by having it strike against the flat surface of the piston eliminates backlash.
FS(a) FS(b) Fr Reduced backlash Even with a single rack design, the use of a special construction minimizes backlash. CRJ1 CRJ05 Model 30 25 Fr Allowable load (N) 25 20 FS(a) 25 20 FS(b) 6 5 Pinion gear Output shaft size (mm) Stopping the pinion gear by having it strike against the flat surface of the piston eliminates backlash.
Fs(a) Fs(b) Size Allowable radial load Fr (N) Allowable thrust load (N) Fr Fsa Fsb Load Load Bearing Thrust bearing Flexible coupling Fig. 2 Bearing Operation of shaft couplings As in Fig. (3), alignment of the rotary actuator and the mating axis is necessary when the rotary actuator Is used with its axis lengthened, If misaligned, the axis is applied with excessive bend moment.
Oistance btween spot wlder capped elclrcde and auto switch at 15000 A:, = 40rnm E a *i"l fr-a \r W'^ Special High Magnetic Field Auto Switches Auto switch is designed to tunction in high magnetic fields, unlike conventional types and can be used as close as 2" from a magnetic field environment displacing 20,000 Amps.
Oistance btween spot wlder capped elclrcde and auto switch at 15000 A:, = 40rnm E a *i"l fr-a \r W'^ Special High Magnetic Field Auto Switches Auto switch is designed to tunction in high magnetic fields, unlike conventional types and can be used as close as 2" from a magnetic field environment displacing 20,000 Amps.
Unit: N Load direction Fsb Model Fsa Fr Fsa Fsb CRB2BW, CRBU2W10 CRB2BW, CRBU2W15 CRB2BW, CRBU2W20 CRB2BW, CRBU2W30 CRB2BW, CRBU2W40 CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100 9.8 14.7 9.8 Fr Long-shaft side 9.8 14.7 9.8 19.6 24.5 19.6 24.5 29.4 24.5 40 60 40 196 245 196 Short-shaft side Short-shaft side Long-shaft side 340 390 340 490 490 490 539 588 539 99 Series CRB2/CRBU2/CRB1 Inertial Moment
Current consumption 12.5A (Peak current 18A) connector Insulation resistance 50M or more (DC500V) J.S.T. Mfg. Over voltage category Category I 2 DC24VJFA connector J4000 series Fan speed control function SC02B-J42SK-GHXR Pollution degree Pollution degree II Only trained personnel should handle or operate the product.
(COM DC12/24V ) DC12/24V (COM GND ) DC 12V10 %,60mA , , BCD //(100ms) 5 / 5ms ()/60ms () RS-232C NPN PNP NPN PNP Max DC30V 50mA Max DC30V 50mA Max DC30V 50mA Max DC30V 50mA AC100 AC100 AC100 AC100 DC24V DC24V DC24V DC24V 240V 240V 240V 240V (10%) (10%) (10%) (10%) (10%) (10%) (10%) (10%) 20VA 10W 20VA 10W 20VA 10W 20VA 10W AC : AC1500V,1 : AC500V,1 AC :DC500V,50M
Vertical Mounting Horizontal Mounting Model Selection Series MSQ Fr M=FrL H L G Load types M=FSH FS G Moment: m x 9.8 x H Allowable moment Thrust load: m x 9.8 Allowable load t : Rotation time (s) 1 / 2 x x 2 allowable energy = 2 / t (: Terminal angular velocity) : Rotation angle (rad) Allowable kinetic energy/Rotation time Ts (Nm) . Load type . Mounting orientation .
Magnet: None, Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread Type: TN (NPT), Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention)
Magnet: None, Mounting: Double Clevis, Bore Size: 40mm, Port Thread Type: NPT, Stroke: 100mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: w/By-Pass, Right-Hand Piping, Drop Prevention, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
output NPN or PNP open collector (same as switch output) Illuminates up when output is ON OUT1: Green; OUT2: Red 1 sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode Note 6): 3-digit fixed 12 to 24 VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) 1000 VAC for 1 min. between external terminal and case 50M
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
Dimensions [mm] Model L1 L2 A B C D E F G J K 138 LEPS10m-25m 152.5 20 22 30 29 20 29 39 88.2 61.8 LEPS10m-50m 163 177.5 24 43 34 50 24 50 60 113.2 LEPS10Lm-25m 124 138.5 20 22 30 29 20 29 39 88.2 47.8 LEPS10Lm-50m 149 163.5 24 43 34 50 24 50 60 113.2 19 Series LEPY/LEPS Specific Product Precautions 1 Be sure to read before handling.
Example) D-Y59AL Impact resistance 1000m/S Insulation resistance 50M or more at 500VDC (between lead wire and case) Withstand voltage 1000VAC for 1min.
Auto Switch Common Specifications Type Reed switch Solid state switch 3 wire: 10A or less 2 wire: 1mA or less None Leakage current 1ms or less Note 3) 1.2ms Operating time 1000m/s {102G} 300m/s {30.6G} Impact resistance 50M or more with a 500VDC megohmmeter (between lead wire & case) Insulation resistance 1000VAC for 1 min.
output is ON, OUT1: Green; OUT2: Red 1 sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode Note 6): 3-digit fixed 12 to 24 VDC (ripple 10% or less) Enclosure Operating temperature range Withstand voltage Insulation resistance Vibration resistance Impact resistance Noise resistance IP65 0 to 50C Resistance 1000 VAC for 1 min. between external terminal and case 50M