Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: 01 [R 1/8(w/M5 Female)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: IM5H [M5 Female Thread Through Through Type (w/Mounting Hole)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
Without pressure sensor Note 1) P1 PSE541 P1A PSE541A P3 PSE543 P3A PSE543A Electrical entry B KQ2P-04 L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: IM5 (M5 Female Thread Through Type)
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±2%F.S., Port Size: IM5 (M5 Female Thread Through Type)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: A (±1%F.S.), Port Size: IM5 (M5 Female Thread Through Type)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: IM5 (M5 Female Thread Through Type)
M5 Modol ~ M6 M8 M5 1M6 M8 M5 M6 M8 M4 IM5 M6 M8 ZPR10g 10 12 12 21 29.9 46 5 6 3 1.7 19 20 i''i: '')I {''::''j ,"i'i 1,;,,1 I 19 1 :P>~2 ZPRIl8 , 20 ZF!R13g 1 3 15 12 21 29.9 46 5 6 3 1.8 '2.~,1 ''2,H 23 22 ZPR13 -,ZPR16g 1 6 18 12.5 21.5 30.' 46.5' 5 6 3.5 1.2 ZPR10 23 22 23 22 22 Deep type (mm) I Model M ,.8 C D E F M:M5xO~J M:M6X1 y G ! G ZPR16 23 22 ZPR20' !
109No.PS-OMW0012-C Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543
Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa
. -67No.PS-OMU0012-C Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564
Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563
Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
Without pressure sensor Note 1) PSE541 P1 PSE541A P1A PSE543 P3 PSE543A P3A Electrical entry KQ2P-04 B L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.
Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa