ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.

ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (P-P) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.

In the case when ventirative or leaky work should be adsorbed, please note that vacuum pressure will not rise. 6 Series ZB Pressure Sensor/Vacuum Pressure Switch Specifications Pressure sensor Vacuum pressure switch Pressure Sensor/ZB1-PS-A (Refer to the PSE series in Best Pneumatics No. 6 and Operation Manual for details.) 0 to 14.6 psi (0 to 101 kPa) ZB1-PS3-A (PSE543) 14.5 to 14.5 psi

Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer

P-1 = A (A B) / 4 H-1 = (A B) / 2 A = Maximum pressure value B = Minimum pressure value For low differential pressure For low pressure For compound pressure PSE533 PSE543 PSE563 For positive pressure For vacuum Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed.

Work 1 Work 2 Work n Atmosphere A = Maximum pressure value B = Minimum pressure value P-1 = A (A B) / 4 H-1 = (A B) / 2 For compound pressure PSE533 PSE543 PSE563 For low differential pressure For low pressure For vacuum For positive pressure Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

Sensor/Digital Pressure Switch for Vacuum Specifications Pressure sensor Digital pressure switch for vacuum Construction Exploded View of Manifold Dimensions Specific Product Precautions How to Order Specifications/ Flow-rate Characteristics Port Layout Pressure Sensor/ZK2-PS-A (Refer to the PSE series in Best Pneumatics No. 6 and Operation Manual for details.) 0 to 101 kPa ZK2-PS3-A (PSE543

Without pressure sensor Note 1) PSE541 P1 PSE541A P1A PSE543 P3 PSE543A P3A Electrical entry KQ2P-04 B L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.

mm 0.3 0.4 0.5 0.6 2 MPa 0.20.55 0.30.55 MPa 0.35 0.4 0.35 0.45 0.35 0.5 L/minANR 3.5 4 6.5 8.5 10 18 /minANR 2 3.5 4.5 7 kPa -85 -90 1 20.5MPa URL http://www.smcworld.com Best Pneumatics No.4 P877898 30m 2 130mm ZB1-PS-A ZB1-PS1-A ZB1-PS3-A PSE541 PSE543 0-101kPa -100100kPa 500kPa DC15V 1k DC1024V10P-P10 15mA 2FS 25 0.4FS 0.2FS 0.8FS 2FS25 O HNBR 2 3 3m0.9mm 2.7X3.2mm

Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa

Model (Sensor unit: Standard model number) ZK2-PS1-A (PSE541) ZK2-PS3-A (PSE543) Rated pressure range 0 to 101 kPa 100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 10 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25C) Linearity 0.4% F.S.

Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: M5 Female Thread Through Type, Option: -

Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±2%F.S., Port Size: M5 Female Thread Through Type, Option: -

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: M5 Female Thread Through Type, Option: -

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: M5 Female Thread Through Type, Option: -

Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±2%F.S., Port Size: M5 Female Thread Through Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: M5 Female Thread Through Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)]

Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: R04 (Ø4 Plug-In Reducer)