Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: A (±1%F.S.), Port Size: IM5 (M5 Female Thread Through Type)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: IM5 (M5 Female Thread Through Type)
M5 Modol ~ M6 M8 M5 1M6 M8 M5 M6 M8 M4 IM5 M6 M8 ZPR10g 10 12 12 21 29.9 46 5 6 3 1.7 19 20 i''i: '')I {''::''j ,"i'i 1,;,,1 I 19 1 :P>~2 ZPRIl8 , 20 ZF!R13g 1 3 15 12 21 29.9 46 5 6 3 1.8 '2.~,1 ''2,H 23 22 ZPR13 -,ZPR16g 1 6 18 12.5 21.5 30.' 46.5' 5 6 3.5 1.2 ZPR10 23 22 23 22 22 Deep type (mm) I Model M ,.8 C D E F M:M5xO~J M:M6X1 y G ! G ZPR16 23 22 ZPR20' !
.: PSE541-M5-X2 The mounting plate is shipped together with the product but does not come assembled. Single unit part nos. p. 16 The piping methods for types with and without a mounting plate are shown in Table 2 below. The pressure sensor is shipped together with the product but does not come assembled. Table 1.
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
Without pressure sensor Note 1) P1 PSE541 P1A PSE541A P3 PSE543 P3A PSE543A Electrical entry B KQ2P-04 L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.
PE Compact pressure sensor P PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM103-A 4.4. FANUC CRX Plug-in software The CRX plug-in software enables easy connection and mounting of the vacuum gripper to the robot. 1.
PE Compact P pressure sensor Supply valve PSE541-R04 P Circuit diagram V -15No. TQ1230001-OM101-D 4.4. URCap Installation and basic setting 1.
PE Compact P pressure sensor PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM102-B 4.4. TMComponent TMComponent is an independent software package for the robot applications and you need to import the software package to use in TMflow (robot software) directly. Here is the list of the SMC Vacuum Gripper TMComponents.
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1C, PSE5*1 VAC SW OTHER SIZE PT, .16500 lb
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JD, PSE5*1 VAC SWITCH 1/8PORT NPT, .47300 lb
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, KD, PSE5*1 VAC SWITCH 1/4PORT NPT, .66138 lb
Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1X, PSE5*1 VAC SW OTHER SIZE(MISC), .15699 lb
. -109No.PS-OMW0012-C Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1
Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa
. -67No.PS-OMU0012-C Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564
ZB-OM00201-B Suction Filter Specifications Filtration rating 30m Filtration area 130 2 Pressure sensor specifications/ ZB1-PS-A Model ZB1-PS1-A ZB1-PS3-A (Sensing part: Standard (PSE543) PSE541 model) Rated pressure range 0 to -101kPa -100 to 100kPa Proof pressure 500kPa Output voltage 1 to 5V DC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, ripple (P-P) 10% at max.