Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.
Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
Applicable fitting size (D) PSE53-R06 6 mm PSE53-R07 1/4 inch With sensor cable -14No.PS-OME0004-G Revision history A: For B: Change template. C: Complete revision. D: Modified errors in text. E: Measurement laws are added. F: Modified errors in text. [October 2017] G: Contents revised in several places.
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance Between whole wires and case 2M (500VDC by megameter) Vibration Resistance 10~500Hz width = 1.5mm or acceleration 10G (Choose the smaller vibration) to X, Y, Z direction (two hours) Shock Resistance 100G X, Y, Z directions (three times for each direction) Protection Structure IP40 PSE51 C O N N E C T I O N T Y P E R06
) 2-wire system (For vacuum and residual pressure) L 3 m Air/Non-corrosive gas Fluid 11 ON: When red LED turns on Indication light Piping specifications Temperature characteristics R06 6 reducer 3% F .S. or less Switch Specifications 1% F .S. or less Repeatability 0.4 4% F .S.
Small, lightweight electronic pressure switch 3.7-1 Air Checker Pressure Switch PS1000/1100 Specifications How to Order PS1000-lL PS1100-lL Model PS L 00 R06 Switch output Present prss.Setting prss.: ON Present prss.Setting prss.: ON 1MPa Max. pressure 0.1 to 0.45MPa 0.1 to 0.4MPa Oper.
Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Sensor range Option None 0 1 2 3 Positive pressure [0 to 1 MPa] Vacuum [0 to 101 kPa] Low pressure [0 to 101 kPa] Compound pressure [101 to 101 kPa] Nil Port size Sensor cable (3 m) M5 R06 R07 M5 x 0.8 6 reducer 1/4 inch reducer L ZSE ISE Option ZSP Connector for pressure sensor controller (1 pc.) + Sensor cable (3 m) Description Part
RoHS How to Order [Option] Q R06 L PS 00 10 Option (CE-compliant ) Nil Q None CE-compliant Output specifications 10 11 12 For positive pressure For vacuum and residual pressure For vacuum The PS1200 series is CEcompliant (with Q) only.