PSE531 and PSE533 are remote vacuum sensors with a 1 to 5V analog signal output. 531 is for low vacuum range of -101 to 0 kPa, while PSE533 is for compound pressure from -101 to 101 kPa. PSE sensors can monitor any non-corrosive, non-flammable gas. The accuracy and environmental capabilities are suitable for general purpose applications.
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
-wire oval cable (0.15 mm2) Sensor cable With sensor cable 42.4 g 42.7 g 49.3 g 41.4 g 41.6 g 43.3 g 44.1 g Weight Without sensor cable 2.9 g 3.2 g 9.8 g 1.9 g 2.1 g 3.8 g 4.6 g 16-3-25 4 Series PSE540 Internal Circuit PSE54 Voltage output type 1 to 5 V Output impedance Approx. 1 k Brown DC (+) Main circuit 1 k Black OUT 10 to 24 VDC + (Analog output) Load Blue DC () Dimensions PSE5R04 R06
PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.
Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.
Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
-600 KN-R06-800 KN-R10-800 D H1 A L1 Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance Between whole wires and case 2M (500VDC by megameter) Vibration Resistance 10~500Hz width = 1.5mm or acceleration 10G (Choose the smaller vibration) to X, Y, Z direction (two hours) Shock Resistance 100G X, Y, Z directions (three times for each direction) Protection Structure IP40 PSE51 C O N N E C T I O N T Y P E R06
whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance Between whole wires and case 2M (500VDC by megameter) Vibration Resistance 10~500Hz width = 1.5mm or acceleration 10G (Choose the smaller vibration) to X, Y, Z direction (two hours) Shock Resistance 100G X, Y, Z directions (three times for each direction) Protection Structure IP40 PSE51 C O N N E C T I O N T Y P E R06
) 2-wire system (For vacuum and residual pressure) L 3 m Air/Non-corrosive gas Fluid 11 ON: When red LED turns on Indication light Piping specifications Temperature characteristics R06 6 reducer 3% F .S. or less Switch Specifications 1% F .S. or less Repeatability 0.4 4% F .S.
Small, lightweight electronic pressure switch 3.7-1 Air Checker Pressure Switch PS1000/1100 Specifications How to Order PS1000-lL PS1100-lL Model PS L 00 R06 Switch output Present prss.Setting prss.: ON Present prss.Setting prss.: ON 1MPa Max. pressure 0.1 to 0.45MPa 0.1 to 0.4MPa Oper.