Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.
Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
-600 KN-R06-800 KN-R10-800 D H1 A L1 Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance Between whole wires and case 2M (500VDC by megameter) Vibration Resistance 10~500Hz width = 1.5mm or acceleration 10G (Choose the smaller vibration) to X, Y, Z direction (two hours) Shock Resistance 100G X, Y, Z directions (three times for each direction) Protection Structure IP40 PSE51 C O N N E C T I O N T Y P E R06
whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance Between whole wires and case 2M (500VDC by megameter) Vibration Resistance 10~500Hz width = 1.5mm or acceleration 10G (Choose the smaller vibration) to X, Y, Z direction (two hours) Shock Resistance 100G X, Y, Z directions (three times for each direction) Protection Structure IP40 PSE51 C O N N E C T I O N T Y P E R06
) 2-wire system (For vacuum and residual pressure) L 3 m Air/Non-corrosive gas Fluid 11 ON: When red LED turns on Indication light Piping specifications Temperature characteristics R06 6 reducer 3% F .S. or less Switch Specifications 1% F .S. or less Repeatability 0.4 4% F .S.
Small, lightweight electronic pressure switch 3.7-1 Air Checker Pressure Switch PS1000/1100 Specifications How to Order PS1000-lL PS1100-lL Model PS L 00 R06 Switch output Present prss.Setting prss.: ON Present prss.Setting prss.: ON 1MPa Max. pressure 0.1 to 0.45MPa 0.1 to 0.4MPa Oper.
Series NCQT Male Rod End NGOQTOOO-OOM Threaded Mounting Holes (Both Ends) NCOQTOAO'OOO f. 056 (s16") #a-32 07s (31) *10-32 106 (11/re") 5/rc-24 150 (11/r-) 3la-24 200 (2) 1/z-20 250 (21/z\ 1/z-20 300 (3) 5/e-18 ,100 (4') e/+-16 MThreaded r06 (r-rlr6") i50 (r.r/2) M-Threaded 25O (2-1f2'l 3(xr (3') 4OO {4') 150 (11/r) Series NCDQT Constnrction / Autn Suitch Capable Double Acting Spring Return
RoHS How to Order [Option] Q R06 L PS 00 10 Option (CE-compliant ) Nil Q None CE-compliant Output specifications 10 11 12 For positive pressure For vacuum and residual pressure For vacuum The PS1200 series is CEcompliant (with Q) only.
-600 KN-R06-800 KN-R10-800 6 4 6 4 6 6 8 8 21.1 25.4 23.7 33.6 31.8 40.1 38 52.3 27 32 30 42 40 50 48 63 14 17 17 22 22 27 27 36 R1/4 R3/8 R3/8 R1/2 R1/2 R3/4 R3/4 R1 D H1 A L1 Reference dimension of "R" thread after installation.