Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate

Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate:

Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate), Made to Order

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate,

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material

This is a legacy product, and replaced byAN700-N12

Please contact us for the latest version.sales@ocaire.com, FILTER ELEMENT (AFW315-N12-*), AIRLINE EQUIPMENT, AFW, 21, AFW NO SIZE RATING

Please contact us for the latest version.sales@ocaire.com, FILTER ELEMENT (AFW315-N12-*), AIRLINE EQUIPMENT, AFW, 21, AFW NO SIZE RATING

Please contact us for the latest version.sales@ocaire.com, FILTER ELEMENT (AFW315-N12-*), AIRLINE EQUIPMENT, AFW, 21, AFW NO SIZE RATING

Please contact us for the latest version.sales@ocaire.com, FILTER ELEMENT (AFW315-N12-*), AIRLINE EQUIPMENT, AFW, 21, AFW NO SIZE RATING

Please contact us for the latest version.sales@ocaire.com, FILTER ELEMENT (AFW315-N12-*), AIRLINE EQUIPMENT, AFW, 21, AFW NO SIZE RATING

) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD

Connector Mounting Position: 1 (Upward), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Specifications: Standard Internal Pilot, Fitting Type: Straight, Power Supply Terminal: N12 (-DC12V)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 2.20853 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 2.20462 lb, ModelApplicable fluidDetection methodRated flow rangeFluid temperatureAccuracyRepeatabilityTemperature characteristicsOperating pressure range Note 2)Proof pressure Note 2)Pressure lossAnalog outputIndicator

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION