DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1815 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1750.00000 lb
DIGITAL FLOW SWITCH FOR WATER IO LINK, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
mode [ HYS] Hysteresis mode [1ot ] Select switch mode [ 1_P] Normal output [1500] 1500 L/min (PF3A703H) [P_1 ] Select input switch operation [3000] 3000 L/min (PF3A706H) [6000] 6000 L/min (PF3A712H) [F 1] Page 35 [ 150] 150 L/min (PF3A703H) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) [ 600] 600 L/min (PF3A712H) [dt1 ] Delay time setting [0.00] 0.00 s [CoL ] Select display colour
switch mode [ P] Normal output [ 1500] 1500 L/min (PF3A703H) [ P] Select input switch operation [ 3000] 3000 L/min (PF3A706H) [ 6000] 6000 L/min (PF3A712H) [F 1] Page 31 [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) [ 600] 600 L/min (PF3A712H) [ CoL] Select display colour [ SoG] Green when ON Red when OFF [F 3] [ FiL] Response time [ 1.0] 1 second Page
3000 L/min 6000 L/min 12000 L/min 30 L/min 3000 L/min PF3A703H 3150 L/min 30 L/min 0 L/min 3150 L/min 60 L/min 6000 L/min PF3A706H 6300 L/min 60 L/min 6300 L/min 0 L/min 120 L/min 12000 L/min 12600 L/min 12600 L/min PF3A712H 120 L/min 0 L/min Rated flow range Set point range Display range Analog Output Output Output Flow/Analog Output 0 L/min A*2 B Voltage output (1 to 5 V)*1 1 V 1.04 V
Item PF3A703H PF3A706H PF3A712H Current flow rate [P_1] Set value of OUT 1500 L/min 3000 L/min 6000 L/min button (UP) Safety Instructions Main display [H_1] Hysteresis of OUT 150 L/min 300 L/min 600 L/min S button (SET) Maintenance Connecting/Disconnecting Align the lead wire connector with the connector key groove, and insert it straight in. Turn the knurled part clockwise.
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
(Displays 0 when the value is (Displays 0 when the value is below 10 L/min) below 20 L/min) 20 to 1050 L/min 40 to 2100 L/min 2.0 0 to 2%F.S. (Displays 0 when the value is (Displays 0 when the value is below 20 L/min) below 40 L/min) 30 to 1050 L/min 60 to 2100 L/min 3.0 0 to 3%F.S.
(Custom range) Relationship between analogue input and digital display Set value A B 200 0 L/min 200 L/min 500 0 L/min 500 L/min 1000 0 L/min 1000 L/min 2000 0 L/min 2000 L/min 3000(Default) 0 L/min 3000 L/min 6000 0 L/min 6000 L/min 12000 0 L/min 12000 L/min 16000 0 L/min 16000 L/min 20 0 L/min 20 L/min USEr Input value (setting) Input value (setting) -31No.PF-OMU0007-D
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)