Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: None, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -, Calibration Certificate: -, Series: -
PU-10M-RRD Silencers/Exhaust Cleaner Series AN/Series AMC Series Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting Series AN00 100 m 150 m Page 5-10-2 30 dB (A) Compact type Space-saving compact type Series AN03 100 m 25 dB (A) Page 5-10-3 Metal case type Exhaust in only one direction.
[F 5] [ FnC] Select FUNC (switching Analogue output 2/ External input) [ oUt] Analogue output PF3A706H Equivalent to M5 3 Nm10% 8 PF3A712H 9 Equivalent to M6 5.2 Nm10% : Arbitrary display mode can be added to the sub display by setting the [F10] sub display.
(For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: Rc, Port Size: 14 (1 1/2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 60 to 6000 l/min, Thread Type: Rc, Port Size: 1 1/2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
, EA (0.01 m), or EC (activated carbon).
This is a legacy product, and replaced byPF3A706H-N14-DS-M, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, JB, IF/PFA 1 1/2 INCH NPT VERSION, 4.29901 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated flow rangeLinearity Note 3)RepeatabilityPressure
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]